作 者:章圣意 姚海滨 董双双 李国占 张洪军 ZHANG Shengyi;YAHaibin;DONG Shuangshuang;LI Guozhan;ZHANG Hongjun(Zhejiang Cangnan Instrument Group,Cangnan 325802,China;College of Metrology and Measurement Engineering,China Jiliang University,Hangzhou 310018,China)
机构地区:[1]浙江苍南仪表集团股份有限公司,浙江苍南325802 [2]中国计量大学计量测试工程学院,浙江杭州310018
出 处:《自动化仪表》2021年第3期8-11,共4页Process Automation Instrumentation
基 金:浙江省重点研发计划基金资助项目(2019C01133);浙江省自然科学基金资助项目(LQ20E060006)。
摘 要:针对超声波流量计易受管道内流态畸变影响的特点,设计了一款由叶片式起旋器、直管混合腔与蜂窝整直器构成的复合整流装置,加装在超声波流量计上游。运用大涡模拟方法对无/有双弯头+半开平板扰流条件下超声波流量计内部的流场进行仿真,分析了测量声道上的速度分布以及整流装置安装间距对其产生的影响,评估了整流装置的性能。结果表明,无整流装置时测量声道上的速度分布出现严重偏斜和畸变,其测量速度与真实流速偏差高达20%;有整流装置时声道上测量速度的偏差降至2.0%以内,整流效果显著。此外,整流装置距上游扰流件不小于5倍管径即可满足其安装要求,大大缩短了超声波流量计对上游直管段的长度要求。设计的复合整流装置拓宽了超声波流量计的实际应用范围。今后将进一步对起旋器结构进行优化以提升其整流效果。Aiming at the characteristic that ultrasonic flowmeter is liable to be affected by the flow pattern distortion in pipeline,a composite rectifying device composed of blade type swirler,straight pipe mixing chamber and honeycomb straightener is designed,which is installed in the upstream of ultrasonic flowmeter.The flow field inside the ultrasonic flowmeter under the condition with or without double elbow plus half-open plate turbulence is simulated by using the large eddy simulation method.The influence of velocity distribution on the measured channel and the spacing between rectifiers installation is analyzed.The performance of the rectifiers is evaluated.The results show that the velocity distribution on the measured channel is seriously skewed and distorted without a retifier,and the deviation between the measured velocity and the real velocity is as high as 20%.When there is a rectifier device,the deviation of the measured speed on the channel is reduced to less than 2.0%,and the rectification effect is significant.In addition,the rectifying device is no less than 5 pipe diameters away from the upstream spoiler to satisfy the installation requirements,which greatly reduces the length requirements of the upstream straight pipe segment of the ultrasonic flowmeter.The design of composite rectifier device amplifies the practical application range of ultrasonic flowmeter.In the future.The structure of the swirler will be further optimized to improve its rectification effect.
关 键 词:超声波流量计 整流器 数值仿真 流态畸变 测量精度
分 类 号:TH39[机械工程—机械制造及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249