叠合板后浇板带无支撑体系施工技术研究  被引量:8

Study on Construction Technology for Unsupported System of Post-cast Strip on Laminated Slab

在线阅读下载全文

作  者:李骏毅 唐颖 Li Junyi;Tang Ying

机构地区:[1]重庆建工第十一建筑工程有限责任公司,重庆400039

出  处:《重庆建筑》2021年第4期52-54,共3页Chongqing Architecture

摘  要:装配式建筑的发展带来了建筑业的极大进步,同时也出现了不少问题,叠合板后浇板带漏浆就是其中一个常见问题。该文通过对后浇板带进行研究,总结出一种新的采用T型螺杆与支承钢管对拉的无支撑体系施工工艺,很好地解决了叠合板后浇板带漏浆问题,同时有效节约了施工成本,可为同类工程项目提供参考。The development of prefabricated buildings has greatly promoted that of the construction industry,but quite a few problems have emerged as well.Slurry leakage in the post-cast strip on laminated slab is one of the common problems.Based on the study of the post-cast strip,this paper summarized a new construction technology of the unsupported system,which adopts T-shaped screw pipes and supporting steel pipes for counter-pulling.Thus,the problem of slurry leakage in the post-cast strip on laminated slab is well solved,with the construction cost effectively saved,which can provide reference for similar engineering projects.

关 键 词:装配式建筑 后浇板带 漏浆 无支撑 施工技术 

分 类 号:TU756.44[建筑科学—建筑技术科学] TU74

 