检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘姝麟 廖家艳 陆秋平 LIU Shu-lin;LIAO Jia-yan;LU Qiu-ping(Guangxi Transportation Science and Technology Group Co.,Ltd.,Nanning 530007,China)
出 处:《水运工程》2021年第4期25-29,共5页Port & Waterway Engineering
摘 要:针对显微镜测厚仪和超声波涂层测厚仪在检测水运工程混凝土涂层厚度时都无法达到相关标准精度要求的问题,通过调研国内外相关规范对超声波涂层测厚仪精度的要求,选定±2μm与±5%两种精度要求,对实际厚度为53、129、252、492、2 349μm的标准片进行厚度测量,并分析测量偏差值与精度要求间的关系。结果表明,±5%的精度要求更适用于水运工程混凝土涂层的厚度检测。For the problem that the detection accuracy of the concrete coating thickness in port and waterway engineering by the microscope and ultrasonic dry-film thickness gages cannot meet the accuracy requirements of relevant standards,we investigate the accuracy requirements of ultrasonic coating thickness gauge in relevant specifications at home and abroad,select two accuracy requirements of ±2 μm and ±5%,measure the thickness of standard samples with the actual thickness of 53 μm,129 μm,252 μm,492 μm and 2 349 μm,and analyze the relationship between measurement deviation and accuracy requirements. The results show that the accuracy of ± 5% is more suitable for the thickness detection of concrete coating in port and waterway engineering.
关 键 词:混凝土防腐涂层 涂层干膜测厚仪 超声波测厚仪 检测 精度
分 类 号:TH873[机械工程—仪器科学与技术] U654[机械工程—精密仪器及机械]