南京市15所基层医疗机构软式内镜清洗消毒现状调研  被引量:2

Investigation on Cleaning and Disinfection Status of Flexible Endoscopy in 15 Primary Health Care Institutions in Nanjing

在线阅读下载全文

作  者:孔懿[1] 刘婷 黄英 张亚英[1] 钱静[1] 戈海[1] 林泓怡[1] KONG Yi;LIU Ting;HUANG ying;ZHANG Yaying;QIAN Jing;GE Hai;LIN Hongyi(Department of Infection Control,Nanjing Drum Tower Hospital,The Affiliated Hospital of Nanjing University Medi-cal School,Nanjing,Jiangsu,210008;Department of Infection Control,The Second Hospital of Nanjing,Nanjing,Ji-angsu,210000)

机构地区:[1]南京大学医学院附属鼓楼医院医院感染管理办公室,江苏南京210008 [2]南京市第二医院医院感染管理科,江苏南京210000

出  处:《江苏卫生事业管理》2021年第4期460-465,共6页Jiangsu Health System Management

摘  要:目的:了解南京市15所基层医疗机构内镜中心的医院感染管理和内镜清洗消毒效果的现状,提出行之有效的改进措施。方法:根据《软式内镜清洗消毒技术规范》设计调查表,通过现场调研的方式,对内镜中心的布局设施、清洗消毒(灭菌)流程、监测和记录、培训和职业安全防护四个方面进行评定。同时,现场抽检内镜的清洗消毒质量。结果:15所基层医疗机构中,93.3%的内镜中心配备四槽以上的清洗消毒站,33.3%配备自动清洗消毒机,60.0%每天(或每次)对内镜进行测漏,40.0%每季度开展内镜消毒效果监测,约46.7%为工作人员配备防护用品和开展培训。现场抽检的结果,内镜的消毒质量合格率在80%-90%。结论:目前我市基层医疗机构内镜中心的医院感染管理仍存才诸多问题,需采取多方面的改进策略,以建立完善的管理制度和流程。Objective:This study investigates the quality of nosocomial infection management and the cleaning and disinfection effects of flexible endoscopes in 15 primary medical institutions,to find common problems existing in the endoscopy centers and propose effective improvements measures.Method:Design a survey form according to“Technical Specifications for Cleaning and Disinfection of Soft Endoscopes”.Through the method of on-site investigation,the layout facilities,and cleaning and disinfection process,monitoring and recording,training and occupational safety protection of the endoscopy centers were evaluated.At the same time,we inspected the quality of cleaning and disinfection of the endoscope.Results:Among the 15 primary medical institutions,93.3%of the endoscopy centers are equipped with more than four tank cleaning and disinfection stations,33.3%are equipped with automatic cleaning and disinfection machines,60.0%carry out leak testing of endoscopes every day,and 40.0%carry out disinfection effect monitoring every quarter.46.7%of the staff are equipped with protective equipment and regular training is carried out.According to the results of spot inspection,the qualified rate of disinfection quality of the endoscope is 80%-90%.Conclusion:At present,the management quality of the endoscopy center of the primary medical institutions has not reached a satisfactory level.It is still necessary to further improve the hardware conditions and improve the management system.

关 键 词:软式内镜 清洗 消毒 现状调查 基层医疗机构 

分 类 号:R197.39[医药卫生—卫生事业管理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象