检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:方玲[1,2] 吴依繁 程光敏 徐星铭[4] 赵珉[4] 夏泉[1,2] FANG Ling;WU Yifan;CHENG Guangmin;XU Xingming;ZHAO Min;XIA Quan(Department of Pharmacy,the First Affiliated Hospital of Anhui Medical University,Hefei 230022,China;The Grade 3 Pharmaceutical Chemistry Laboratory of National Administration of Traditional Chinese Medicine,Hefei 230022,China;Anhui University of Chinese Medicine,Hefei 230012,China;Department of Nephrology,the First Affiliated Hospital of Anhui Medical University,Hefei 230022,China)
机构地区:[1]安徽医科大学第一附属医院药剂科,合肥230022 [2]国家中医药管理局中药化学三级实验室,合肥230022 [3]安徽中医药大学药学院,合肥230012 [4]安徽医科大学第一附属医院肾脏内科,合肥230022
出 处:《药学服务与研究》2021年第2期128-132,145,共6页Pharmaceutical Care and Research
基 金:中华医学会临床药学分会科研基金(320.6750.19090-17)。
摘 要:目的:建立测定血浆和腹膜透析液中万古霉素浓度的HPLC法,为腹膜透析相关性腹膜炎患者的药物浓度监测提供参考。方法:采用Waters Symmetry C18色谱柱(250 mm×4.6 mm,5μm),以甲醇∶乙腈∶0.05 mol/L KH2PO4=11∶2∶87为流动相,检测波长236 nm,柱温30℃,流速1.0 ml/min,检测血浆和腹膜透析液中万古霉素的浓度。结果:血浆中的万古霉素浓度在0.2~40μg/ml范围内线性关系良好(r=0.998),定量限为0.2μg/ml,提取回收率为85.11%~89.15%,方法回收率为86.72%~89.51%。腹膜透析液中的万古霉素浓度在0.2~16μg/ml范围内线性关系良好(r=0.999),定量限为0.2μg/ml,提取回收率为88.13%~90.18%,方法回收率为87.10%~103.24%。本研究共纳入36例腹膜透析相关性腹膜炎患者,31例(86.11%)患者的血浆和腹膜透析液中万古霉素浓度达标;而尿量>500 ml/d的患者,其血浆和腹膜透析液中万古霉素浓度偏低。结论:该方法可满足腹膜炎患者的万古霉素浓度监测,对于尿量>500 ml/d的患者,需适当增加万古霉素的剂量并加强监测,以维持安全有效的药物浓度。Objective:To establish a high performance liquid chromatography(HPLC)method for the determination of vancomycin in human plasma and peritoneal dialysate,so as to provide a methodological basis for clinical monitoring of vancomycin concentration in the patients with peritoneal dialysis-related peritonitis.Methods:Waters Symmetry C18 column(250 mm×4.6 mm,5μm)was applied.The mobile phase was methanol∶acetonitrile∶0.05 mol/L KH2PO4=11∶2∶87 at a flow rate of 1.0 ml/min,the detection wavelength was 236 nm and the column temperature was 30℃.The concentration of vancomycin in plasma and peritoneal dialysate was determined.Results:Vancomycin displayed good linearity within the range of 0.2-40μg/ml(r=0.998)in plasma and the lower limitation of quantification was 0.2μg/ml.The extraction rates were 85.11%-89.15%,and the recovery rates were 86.72%-89.51%.In peritoneal dialysate,vancomycin displayed good linearity within the range of 0.2-16μg/ml(r=0.999)and the lower limitation of quantification was 0.2μg/ml.The extraction rates were 88.13%-90.18%,and the recovery rates were 87.10%-103.24%.Of the 36 patients included in the study,31(86.11%)reached the effective concentration of vancomycin.However,the patients with a urine output of more than 500 ml/d had a lower concentration of vancomycin both in plasma and peritoneal dialysate.Conclusion:The method could meet the need of vancomycin concentration monitoring in the patients with peritonitis.Furthermore,for the patients with a urine output of more than 500 ml/d,vancomycin dosage should be appropriately increased and monitoring should be intensified,so as to ensure a safe and effective drug concentration.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15