IC厌氧反应器在酸奶行业废水中的实际运用探讨  被引量:1

Discussion on the Practical Application of IC Anaerobic Reactor in Yoghurt Industry Wastewater

在线阅读下载全文

作  者:黄强[1] Huang Qiang(Design Department,Nantong Daheng Environmental Engineering Co,Ltd.,Nantong 226014,China)

机构地区:[1]南通大恒环境工程有限公司设计部,江苏南通226014

出  处:《广东化工》2021年第3期103-104,共2页Guangdong Chemical Industry

摘  要:IC厌氧反应器属于第三代高效厌氧反应器,近年来受到广泛关注及研究。本文笔者以IC厌氧反应器在某酸奶企业中的实际运用为例,详细介绍了该工程的相关设计、运行参数。实际运行效果表明,采用IC厌氧反应器COD_(cr)去除率可达85%以上。该项目的成功运行对今后类似工程选用IC厌氧反应器具有一定的参考意义。IC anaerobic reactor belongs to the third generation of high-efficiency anaerobic reactor,which has been widely concerned and studied in recent years.Taking the practical application of IC anaerobic reactor in a yoghurt enterprise as an example,the relevant design and operation parameters of this project are introduced in detail.The practical operation results show that the removal rate of COD_(cr) in IC anaerobic reactor can reach more than 85%.The successful operation of this project has certain reference significance for the selection of IC anaerobic reactor in similar projects in the future.

关 键 词:IC 酸奶行业 设计参数 运行效果 

分 类 号:X5[环境科学与工程—环境工程]

 