水平钢筋连接对装配式复合剪力墙节点抗震性能的影响  被引量:5

Influence of horizontal steel bar connection on seismic performance of assembled composite shear wall joints

在线阅读下载全文

作  者:马少春[1,2] 方宏远 鲍鹏[1] 姜忻良[3] MA Shaochun;FANG Hongyuan;BAO Peng;JIANG Xinliang(School of Civil Engineering and Architecture,Henan University,Kaifeng 475001,Henan,P.R.China;College of Water Conservancy&Engineering,Zhengzhou University,Zhengzhou 450001,P.R.China;School of Civil Engineering,Tianjin University,Tianjin 300072,P.R.China)

机构地区:[1]河南大学土木建筑学院,河南开封475004 [2]郑州大学水利科学与工程学院,郑州450001 [3]天津大学建筑工程学院,天津300072

出  处:《土木与环境工程学报(中英文)》2021年第3期44-50,共7页Journal of Civil and Environmental Engineering

基  金:国家住房和城乡建设部科技计划(2018-K9-065);中国博士后科学基金(2018M632805);河南省高等学校重点科研项目(18A560007);开封市科技攻关项目(2001010)。

摘  要:为研究水平钢筋连接方式对复合剪力墙节点抗震性能的影响规律,设计了水平钢筋伸入暗柱或不伸入暗柱两类组合节点。在循环荷载作用下,对两类节点共4个试件分别进行了抗震试验。通过对复合剪力墙节点的受力变形、破坏特征、滞回特性、延性以及耗能能力等方面进行研究,分析了复合剪力墙连接节点的抗震性能。通过对承载及变形、延性及耗能等指标进行对比分析发现:水平钢筋连接节点的开裂、屈服及极限荷载分别提高了2.42%、10.84%和9.25%;延性系数提高了10.26%;耗能系数提高了8.70%。研究结果表明:对剪力墙节点进行合理配筋和连接,可以有效地提高节点试件的整体抗震性能。In order to study the influence of the horizontal steel bar connection method on the seismic performance of the composite shear wall joints,this paper designed two types of composite joints,which were horizontal reinforcements with or without embedded column.Under cyclic loading,a total of four specimens of two types of joints were subjected to seismic tests.By studying the deformation,failure characteristics,hysteretic characteristics,ductility and energy dissipation capabilities of the composite shear wall node,the seismic performance of the composite shear wall connection node is analysed.Through comparative analysis of bearing and deformation,ductility,energy consumption and other indicators,it is obtained that the cracking,yielding and ultimate load of the joints of horizontal steel bars are increased by 2.42%,10.84%and 9.25%respectively;the ductility coefficient is increased by 10.26%;the energy consumption coefficient has been increased by 8.70%.It can be seen that the overall seismic performance of the joint specimens can be effectively improved by reasonable reinforcement and connecting the shear wall nodes.

关 键 词:低周反复试验 剪力墙节点 抗震性能 装配式 滞回曲线 

分 类 号:TU398[建筑科学—结构工程] TU364

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象