特高压换流站站用电备自投越级动作的故障分析及改进措施  被引量:3

Analysis on overstep tripping of UHVDC converter station auxiliary power system bus-bar automatic transfer switch and its improvement

在线阅读下载全文

作  者:李然 孙毅 金铭 吕力 LI Ran;SUN Yi;JIN Ming;LÜLi(Maintenance Branch,State Grid Jiangsu Electric Power Co.,Ltd,Nanjing 211100)

机构地区:[1]国网江苏省电力有限公司检修分公司,南京211100

出  处:《电气技术》2021年第5期68-72,共5页Electrical Engineering

摘  要:站用电系统在特高压换流站中属于极其重要的辅助系统,其供电可靠性直接影响换流站的安全稳定运行。本文以特高压淮安换流站为例,详细介绍了换流站站用电系统的主体结构及备自投的动作逻辑,在此基础上对一起特高压换流站站用电备自投越级动作的故障进行了详细的分析,指出故障原因为10kV开关信号回路设计错误。针对该原因提出了相应的改进措施,并通过试验验证了该措施的正确性。Auxiliary power system is an extremely important system in ultra high voltage direct current(UHVDC)converter station,and its reliability directly affects the safe and stable operation of converter station.The main structure of station auxiliary power system and the automatic switchingon/off logic of bus-bar automatic transfer switch(BATS)based on Huaian converter station is introduced in this paper.On the basis of that,an overstep tripping of UHVDC converter station bus-bar automatic transfer switch is analyzed and the root cause of the fault that is the design error of 10kV switch signal circuit is pointed out.For this reason,the corresponding improvement measures are put forward,and the effectiveness of the improvement is verified by experiments.

关 键 词:换流站 站用电 备自投 越级动作 故障分析 改进措施 

分 类 号:TM721.1[电气工程—电力系统及自动化]

 