臭氧接触池在污水深度处理中的应用  

Application of Ozone Contact Tank in Advanced Wastewater Treatment

在线阅读下载全文

作  者:张荻[1] 张言 ZHANG Di;ZHANG Yan(Jinan Qingyuan Water Affairs Group Co.,Ltd.,Jinan,Shandong 250011,Chnia;Hydraulic Engineering Service Center of Jinan City,Jinan,Shandong 250015,Chnia)

机构地区:[1]济南市清源水务集团有限公司,山东济南250011 [2]济南市水利工程服务中心,山东济南250015

出  处:《山东水利》2021年第4期8-10,共3页Shandong Water Resources

摘  要:臭氧接触池的设计不但与臭氧的利用率、灭菌消毒或臭氧氧化的效果及经济成本息息相关,同时由于臭氧的强氧化性和危险性,对池体本身及厂区环境的安全性也至关重要。本文从池型设计、尾气破坏、呼吸阀等方面对臭氧接触池设计进行了概述。The design of ozone contact tank is not only closely related to the utilization rate of ozone,the effect of sterilization or ozone oxidation and the economic cost,but also is very important to the safety of the tank itself and the factory environment,because of the strong oxidation and danger of ozone.In this paper,the design of ozone contact tank is summarized from the aspects of tank design,exhaust damage and respiration valve.

关 键 词:臭氧 氧接触池 尾气破坏 呼吸阀 

分 类 号:X703[环境科学与工程—环境工程]

 