多级泵站系统能耗的计算方法  被引量:5

Calculation Method for Energy Consumption of Multistage Pumping Station System

在线阅读下载全文

作  者:董加新 王智 王玉川[1,2] 陈晓俊 杨建国[1,2] DONG Jia-xin;WANG Zhi;WANG Yu-chuan;CHEN Xiao-jun;YANG Jian-guo(College of Water Resources and Architectural Engineering,Northwest Agricultural and Forestry University,Yangling 712100,Shaanxi Province,China;Key Laboratory of Agricultural Soil and Semi-arid Areas of Education,Northwest Agricultural and Forestry University,Yangling 712100,Shaanxi Province,China;Weinan Donglei Yellow River Pumping Engineering Administration,Heyang 715300,Shaanxi Province,China;Institute of Water Resources Research of Pastoral Area,Ministry of Water Resources,Hohhot 010020,China)

机构地区:[1]西北农林科技大学水利与建筑工程学院,陕西杨凌712100 [2]西北农林科技大学旱区农业水土工程教育部重点实验室,陕西杨凌712100 [3]渭南市东雷抽黄工程管理中心,陕西合阳715300 [4]水利部牧区水利科学研究所,呼和浩特010020

出  处:《中国农村水利水电》2021年第5期43-48,共6页China Rural Water and Hydropower

基  金:国家自然科技基金项目(51809218);陕西省水利科技项目(2018slkj-8)。

摘  要:在总结多级泵站系统工作组合方式的基础上,推导了多级泵站系统固有能耗参数和实际能耗参数的计算方法,其中固有能耗参数是指多级泵站系统无分流情况下的能耗参数。以东雷抽黄灌区2019年冬季灌溉新民多级泵站系统的实测数据为例,讨论了固有能耗参数与实际能耗参数之间的关系,分析了水泵机组及泵站系统的运行情况。对于一个固定组成的多级泵站系统,各水泵机组性能稳定情况下固有能耗参数为一定值,其实际能耗参数随工况变化而变化,固有装置效率通常小于实际装置效率。水泵机组及泵站系统的能耗参数可作为运行状态监测、最优运行调度方案和节能改造的标准,同时也可为灌区水价的制定及灌区财政补贴提供依据。On the basis of summarizing the working combination of the multi-stage pumping station system,the calculation methods of the inherent energy consumption parameters and the actual energy consumption parameters of the multi-stage pumping station system are derived,the inherent energy consumption parameters refer to the energy consumption parameters in the case of no diversion in the multi-stage pumping station system.Taking the measured data of the Xinmin system for 2019 winter irrigation in Donglei Yellow River pumping system as an example,the relationship between the inherent energy consumption parameter and the actual energy consumption parameter is discussed,and the operation of the pump unit and pumping station system is analyzed.For a fixed multi-stage pumping station system,the inherent energy consumption parameter is a certain value when the performance of each pump unit is stable,and its actual working efficiency varies with operating conditions.The inherent device efficiency is usually less than the actual device efficiency.The energy consumption parameters of the pump unit and the pumping station system can be used as standards for operating status monitoring,optimal operation scheduling and energy-saving transformation,and can also provide a basis for the formulation of irrigation district water prices and financial subsidies for irrigation districts.

关 键 词:多级泵站 系统能耗 能源单耗 能耗系数 计算方法 

分 类 号:TV675[水利工程—水利水电工程] S277.1[农业科学—农业水土工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象