作 者:王艳红 李俊丽 侯文华 王楠 苗永国 WANG Yan-hong;LI Jun-li;HOU Wen-hua(Cardiology Department,Handan People's Hospital,Handan 056001,China;不详)
出 处:《中国医学装备》2021年第5期43-47,共5页China Medical Equipment
基 金:邯郸市科学技术研究与发展计划(1823208067ZC)“曲美他嗪联合稳心颗粒对心力衰竭患者细胞炎性因子的影响”。
摘 要:目的:探讨静脉内心电图引导经外周静脉置入中心静脉导管(PICC)技术尖端定位的应用效果。方法:选择医院收治的170例放置三向瓣膜PICC的患者,并严格按照纳入标准进行病例筛选。应用筛检试验对置管后患者的心电图定位方法和X射线片进行对比,并对患者的心电图P波与R波比值(P/R)与心电图P波高度的均数和95%置信区间进行对比分析。结果:应用心电图引导PICC尖端定位的方法,其真实性、实用性及可靠性指标均较好。X射线片与PICC尖端位置判断的特异度、假阳性率、灵敏度、假阴性率和粗符合率分别为91.18%、8.82%、98.43%、1.57%和96.89%,约登指数为0.90、阳性似然比为11.16;心电图定位技术阴性与阳性预测值分别为93.34%、97.66%;房颤患者的X射线片与心电图定位对比,特异度为100%,灵敏度为92.32%;P/R比值和P波高度分别为0.78±0.45和0.92±0.037,95%置信区间分别为0.69~0.87和0.84~0.99;f波高度、f'波高度和(f'-f)/f比值分别为(1.06±0.25)cm、(1.68±0.34)cm和(0.60±0.16),(f'-f)/f比值的95%置信区间为0.52~0.69。结论:房颤患者应用心电图定位PICC尖端位置时,不易导致异位且精准度较高,具有较高的临床应用价值。Objective:To explore the application effect of tip localization of peripherally inserted central catheter(PICC)was guided by intravenous electrocardiogram.Methods:170 PICC patients with three-way valve were selected,and these cases were screened according to the in strict inclusion criteria.Screening test was used to compare the location method of electrocardiograph(ECG)and X-ray film of patients after catheterization,and the ratio of P wave to R wave(P/R)of ECG,the mean value and 95%confidence interval of P wave height of ECG were further compared and analyzed.Results:The indicators of accuracy,practicability and reliability of ECG-guided PICC tip localization were favorable.The specificity,false positive rate,sensitivity,false negative rate and crude coincidence rate were 91.18%,8.82%,98.43%,1.57%and 96.89%between X-ray film and PICC tip location,respectively.The Youden index was 0.90 and the positive likelihood ratio was 11.16,respectively.And the negatively and positively predictive values of ECG location method were 93.34%and 97.66%respectively.Comparison of X-ray film and ECG location in patients with atrial eminence indicated that the specificity and sensitivity were 100%and 92.32%,respectively.The P/R ratio and P wave height were 0.78±45 and 0.92±0.037,respectively.And 95%confidence intervals were 0.69-0.87 and 0.84-0.99,respectively.The f wave height,f'wave height and the ratio of(f'-f)/f were(1.06±0.25)cm,(1.68±0.34)cm and(0.60±0.16),and the 95%confidence interval of the ratio of(f'-f)/f was 0.52-0.69.Conclusion:It is not easy to cause ectopia when ECG is used to locate the tip of PICC in patients with atrial eminence,and the accuracy is higher.This technique has greater clinical application value.
关 键 词:静脉导管 外周静脉置入中心静脉导管(PICC) 心电图 筛检试验
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49