Observation and measurement of applied anatomical features for thoracic intervertebral foramen puncture on computed tomography images  被引量:3

在线阅读下载全文

作  者:Ran Wang Wei-Wei Sun Ying Han Xiao-Xue Fan Xue-Qin Pan Shi-Chong Wang Li-Juan Lu 

机构地区:[1]Department of Pain Management,Nanjing Drum Tower Hospital,Clinical College of Xuzhou Medical University,Nanjing 210008,Jiangsu Province,China [2]Department of Pain Management,Nanjing Drum Tower Hospital,The Affiliated Hospital of Nanjing University Medical School,Nanjing 210008,Jiangsu Province,China

出  处:《World Journal of Clinical Cases》2021年第18期4607-4616,共10页世界临床病例杂志

基  金:Supported by The Key R&D Project in Jiangsu Province,No.BE2017603 and No.BE2017675;the Key Program of Medical Science and Technology Development Projects in Nanjing,No.ZKX19016.

摘  要:BACKGROUND Thoracic intervertebral foramen puncture is the key step for interventional therapy on the thoracic nerve roots or dorsal root ganglia.The anatomical features of the thoracic spine are complex,and puncture injury to the pleura,blood vessels,spinal cord,and other tissues may cause serious complications.The spatial anatomical characteristics and related parameters for thoracic intervertebral foramen puncture remain poorly understood.AIM To observe and summarize the spatially applied anatomical characteristics for intervertebral foramen puncture on different vertebral segments.METHODS A total of 88 patients(41 males and 47 females)who underwent thoracic minimally invasive interventional treatment at Nanjing Drum Tower Hospital from January 2019 to June 2020 were included.Computed tomography images of 167 thoracic vertebral segments scanned in the prone position were collected.The width of the intertransverse space(D_(P)),the height of the rib neck/head above the lower transverse process(D_(R)),the width of the lateral border of the articular process/lamina(W_(P)),and the width of the posterior border of the vertebral body(W_(V))were measured.At the upper 1/3 of the intervertebral foramina,the horizontal inclination angle(α)from the lateral border of the articular process/lamina to the posterolateral border of the vertebral body was measured.The ratios D_(R)/D_(P) and W_(P)/W_(V) were calculated.The intervertebral foramen parameters were compared between segments.RESULTS No rib head/neck occlusion(D_(R)/D_(P)>0)was found in the intertransverse spaces of T1-2 and T12-L1.The incidence of occlusion for the upper thoracic segments(T1-5,n=138),middle thoracic segments(T5-9,n=116),and lower thoracic segments(T9-L1,n=80)were 76.81%,100%,and 82.50%,respectively.The incidence of occlusion for the middle thoracic segments was significantly higher than that for the upper and lower thoracic segments(P<0.05).The incidence of>1/2 occlusion(D_(R)/D_(P)>1/2)for the upper,middle,and lower thoracic segments was 7.97%,74.14

关 键 词:Thoracic intervertebral foramen PUNCTURE Computed tomography Threedimensional reconstruction RIB 

分 类 号:R681.5[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象