Fenton法预处理环己酮肟化废水的研究  

Pretreatment of Cyclohexanone oximation wastewater by Fenton oxidation process

在线阅读下载全文

作  者:顾效纲 张军政 王知强 郭彩荣 梁丹 张岩岗 GU Xiao-gang;ZHANG jun-zheng;WANG Zhi-qiang;GUO Cai-rong;LIANG Dan;ZHANG Yan-gang(School of Municipal&Environmental Engineering,Henan University of Urban Construction,Pingdingshan 467036,China;Beijing Sinor Water Technology Co.,Ltd.,Beijing 100000,China)

机构地区:[1]河南城建学院市政与环境工程学院,河南平顶山467036 [2]北京赛诺水务科技有限公司,北京100000

出  处:《河南城建学院学报》2021年第2期64-66,72,共4页Journal of Henan University of Urban Construction

摘  要:采用Fenton法对环己酮肟化废水进行预处理,通过单因素试验,研究了影响COD去除效果的几个因素,确定工艺参数以pH为3,FeSO_(4)·7H_(2)O投加量为3 g/L,H_(2)O_(2)投加量为5 mL/L,反应时间为40 min最为适宜。在该工艺条件下,废水COD去除率可达20%~40%,B/C由原来的0提高到0.15~0.18。结果表明,环己酮肟化废水经Fenton法预处理后可生化性得到明显改善。Fenton oxidation as a pretreatment method was used to treat cyclohexanone oximation wastewater.The influence factors associated with the COD efficiency were studied through single factor experiment.The optimum parameters were obtained as follow:pH 3,FeSO_(4)·7H_(2)O 3 g/L,H_(2)O_(2)5 mL/L and reaction time 40 min,and the COD removal rate were reached 20%to 40%,and the ratio B/C(BOD5/COD)was increased from 0 to 0.15~0.18.The results showed that the biodegradability of cyclohexanone oximation wastewater was improved obviously by Fenton oxidation method.

关 键 词:FENTON法 环己酮肟化废水 预处理 可生化性 

分 类 号:X703[环境科学与工程—环境工程]

 