摘  要:电力变压器不同电压等级的绕组浸在油箱内,绕组引线经电缆或套管引出到油箱外部,与其他设备相连,实现电能的传输。本文介绍了绕组引线经电容式套管引出、电缆引出和纯瓷套管引出等几种引出方式,并对它们的适用情况及优缺点进行分析。The windings of power transformer with different voltage levels are immersed in the oil tank.The winding is led out to the outside of the oil tank via a cable or bushing which connecting with other equipment to realize the transmission of electric energy.This paper introduces several kinds of lead-out methods of transformer winding,such as capacitance bushing,cable and pure porcelain bushing.Also their applicability,advantages and disadvantages are analyzed.

关 键 词:变压器 高压绕组 套管 渗漏油 