ITER第一壁铍铜连接部件在高热负荷作用下的热性能分析  被引量:1

Study on thermal performance of Be/Cu joint of ITER first wall components under high heat flux

在线阅读下载全文

作  者:赵宝玲 谌继明[2] 吴晶 康伟山[2] ZHAO Bao-ling;CHEN Ji-ming;WU Jing;KANG Wei-shan(China National Nuclear Industry Corporation 404,Jiayuguan 730050;Southwestern Institute of Physics,Chengdu 610041)

机构地区:[1]中核四0四有限公司,嘉峪关730050 [2]核工业西南物理研究院,成都610041

出  处:《核聚变与等离子体物理》2021年第2期157-161,共5页Nuclear Fusion and Plasma Physics

摘  要:对ITER屏蔽包层第一壁板铍铜连接件在高热负荷作用下的传热性能进行了分析,模拟了第一壁铍铜连接手指部件的热应力和热应变,得到其对应的热疲劳寿命。计算结果表明,在局部4.7MW·m^(-2)高热负荷作用和ITER水冷条件下,现有设计方案中的铍铜连接件的热性能和热疲劳性能均满足设计要求。The thermal performance of Be/Cu joint of ITER first wall components was studied under the high heat flux. The thermal stress and thermal strain of Be/Cu joint are simulated, and the corresponding thermal fatigue life is obtained. The results indicate that the thermal and thermal fatigue performances of the current design of Be/Cu joint under 4.7 MW·m^(-2) high heat flux and ITER normal operation condition can meet the design requirements.

关 键 词:第一壁 铍铜连接件 热性能 热疲劳 

分 类 号:TL626[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象