检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:梁政 申江[1] 魏国东 周成君 LIANG Zheng;SHEN Jiang;WEI Guo-dong;ZHOU Cheng-jun(Tianjin Key Laboratory of Refrigeration Technology,Tianjin University of Commerce,Tianjin,China,Post Code:300134;Beijing Jingkelun Refrigeration Equipment Co.Ltd.,Beijing,China,Post Code:100000)
机构地区:[1]天津商业大学天津市制冷技术重点实验室,天津300134 [2]北京市京科伦冷冻设备有限公司,北京100000
出 处:《热能动力工程》2021年第5期82-89,共8页Journal of Engineering for Thermal Energy and Power
基 金:中国标准化研究院院长基金重大项目《资源高效利用标准化技术体系构建和应用》(542019Y-6659)。
摘 要:为拓宽水蒸气热泵在余热回收中的工作温区,降低水蒸气压缩机的排气温度,对采用喷水降温螺杆压缩机的水蒸气热泵系统及其主要部件建立热力学模型,研究了螺杆压缩机喷水温度,及最佳喷水温度下蒸发温度、冷凝温度对系统性能的影响。结果表明:喷水可以有效降低压缩机排气温度,喷水温度在73~87℃之间可保证压缩机运行在报警温度之下;压缩机耗功和冷凝器放热量随喷水温度的升高先增加后降低,在喷水温度为80℃时系统性能系数(EER)最佳;最佳喷水温度下,蒸发温度提高,蒸发器吸热量、压缩机耗功、冷凝器放热量及EER增大,压缩机压比降低;冷凝温度提高,压缩机耗功、压比增大,冷凝器放热量和EER降低。In order to broaden the working temperature range of steam heat pump in waste heat recovery, reduce the exhaust temperature of steam compressor. The thermodynamic model is established for the steam heat pump system and its main components with water spray cooling screw compressor. The effects of the spray water temperature of the screw compressor, the evaporation temperature and the condensation temperature at the optimal spray water temperature on the performance of the system were analyzed.The results show that: Water spray can reduce the compressor exhaust temperature effectively.The water spray temperature between 73~87 ℃ can ensure that the compressor operates below the alarm temperature;The power consumption of the compressor and the condenser heat release of the condenser increase at first and then decrease with the increase of the water spray temperature.EER is best when the water spray temperature is 80 ℃;At the optimal water spray temperature, the evaporation temperature, evaporator heat absorption, compressor power consumption, condenser heat release and EER increase, while the compressor pressure ratio decreases;Condensation temperature, compressor power consumption and pressure ratio increase, while condenser heat release and EER decrease.
分 类 号:TH45[机械工程—机械制造及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.218.96.239