600MW发电机组TPY级电流互感器暂态性能校验分析  被引量:3

Verification and Analysis on Transient Characteristics of TPY Class Current Transformer for 600MW Generating Unit

在线阅读下载全文

作  者:罗丽佳 LUO Lijia

机构地区:[1]内蒙古京泰发电有限责任公司,内蒙古鄂尔多斯010300

出  处:《青海电力》2021年第2期32-37,共6页Qinghai Electric Power

摘  要:为检验投产后发电机组TPY级电流互感器暂态性能是否满足保护动作性能要求,以某电厂600 MW发电机组TPY级电流互感器配置为基础,通过分析TPY级电流互感器暂态性能校验判据,提出系统性暂态性能校验方案,实现校验流程规范化。结合机组不同接线方式下实例校验分析,对该方案实现过程进行具体阐述,为同类机组开展TPY级电流互感器暂态性能校验工作提供参考。In order to prove the conformity of the transient characteristics of the TPY class current transformer forgenerating unit in service with the requirements for the protection system performance,Based on the configuration of TPY class current transformer for the 600 MW generating unit in a power plant,by analyzing the verification criterion for the TPY class current transformer’s transient characteristics,a systematic verification scheme of the transient characteristics of the TPY class current transformer for 600 MW generating unit is proposed to standardize theverification process.With analysis on the practical verifications with different connections,the implementation of the scheme is given in detail to provide a reference for the verification of the TPY class current transformer’s transient characteristics in similar units.

关 键 词:发电机组 TPY级电流互感器 暂态性能 校验方案 

分 类 号:TM452[电气工程—电器]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象