摘  要:通过对3种常见建筑外保温材料从设计到施工过程的分析,探讨了保温材料层间游离水的由来,并有针对性地提出了岩棉板及EPS保温板防坠落的改进措施。同时论述了后续对建筑外保温定期和定量的安全检查机制落实的可能性。Through the analysis of the design and construction process of three kinds of common building external thermal insulation materials,the origin of free water among layers of thermal insulation materials is discussed,and the improvement of anti-shedding measures for rock wool board and EPS thermal insulation board is puts forward.At the same time,it also discusses the possibility of implementing regular and quantitative safety inspection mechanism for building external thermal insulation.