检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张彩云[1] 张朋川[1] 袁璐璐[1] 俞开昌[1] 薛涛[1] ZHANG Cai-yun;ZHANG Peng-chuan;YUAN Lu-lu;YU Kai-chang;XUE Tao(Beijing Origin Water Technology Co.Ltd.,Beijing 102206,China)
机构地区:[1]北京碧水源科技股份有限公司,北京102206
出 处:《中国给水排水》2021年第10期116-119,125,共5页China Water & Wastewater
基 金:北京市资源环境与可持续发展项目(Z171100000717001)。
摘 要:云南大理某城镇污水处理厂设计产水水质达到地表水Ⅲ类标准(湖、库),采用膜生物反应器(MBR)-纳滤(NF)双膜处理工艺。针对产水总磷≤0.05 mg/L的超高标准除磷需求,对该项目的NF工艺段进行除磷衡算和膜系统设计分析,确定了浓水分段双回流、两段元件排列比4∶1的最佳工况条件。实际工程验证结果表明,产水水质稳定达标,其中总磷为0.013~0.042 mg/L,NF工艺段的电耗、药剂、耗材及膜折旧成本合计0.37~0.55元/m3,NF膜系统清洗周期约为1个月。MBR-NF双膜工艺的常规产水水质指标达到地表水Ⅲ类标准(湖、库),并具有较高的环境生态安全性,适用于富营养化敏感水体治理、工业水回用、再生水地下回灌等。To meet the effluent quality as levelⅢcriteria of Environmental Quality Standards for Surface Water(GB 3838-2002)(S-Ⅲ),the MBR-NF process was applied in a municipal wastewater treatment plant(WWTP)in Dali,Yunnan Province.Aiming at the super high effluent requirement of TP≤0.05 mg/L,the phosphorus removal balance and membrane system design were analyzed for the NF process section of this project,and the optimal working conditions of double reflux of concentrate and 4∶1 ratio of two-section element arrangement were determined.The verification results of actual project show that the water quality is stable and up to the standard.Among them,the effluent TP concentration was 0.013-0.042 mg/L.The operational cost including energy,chemicals,consumption materials and NF membrane depreciation was 0.37-0.55 yuan/m3.The duration of a membrane cleaning cycle was about a month.The common effluent indexes of MBR-NF process can meet S-Ⅲ,and have high safety to environmental ecosystem,which is suitable for wastewater treatment in eutrophication sensitive areas,industrial water reuse and wastewater reclamation for groundwater recharge.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28