600MW汽轮发电机定子股线断裂故障的分析  

Analysis of Fracture Fault of Stator Strands of 600MW Steam Turbo-generator

在线阅读下载全文

作  者:刘亿鑫 赵淑媛 薛青裕 贾占峰 宝音太 Liu Yixin;Zhao Shuyuan;Xue Qingyu

机构地区:[1]华电内蒙古能源有限公司,呼和浩特010020 [2]华电包头发电有限公司,内蒙古包头014000

出  处:《上海电气技术》2021年第2期24-28,48,共6页Journal of Shanghai Electric Technology

摘  要:针对600 MW汽轮发电机定子股线断裂故障,进行了现场检查、金相分析、化学成分分析、力学性能分析、断口电镜扫描。通过检查和分析,确认由于疲劳裂纹不断扩展,最终导致定子股线断裂。所做的故障分析可以为同类型故障提供参考。In view of the fracture failure of the stator strands of the 600 MW steam turbo-generator,on-site inspection,metallurgical analysis,chemical composition analysis,mechanical property analysis,and electron microscope scanning of the fracture were carried out.Through inspection and analysis,it is confirmed that due to the continuous expansion of fatigue cracks,the stator strands are eventually broken.The failure analysis done can provide reference for the same type of fault.

关 键 词:汽轮发电机 定子 故障 分析 

分 类 号:TM311[电气工程—电机]

 