加油站罩棚网架结构可靠性鉴定研究  被引量:2

STUDY ON RELIABILITY APPRAISAL METHOD OF GAS STATION CANOPY NET FRAME

在线阅读下载全文

作  者:吴碧野 赵曦辉[3] 武岳[4,5] 戴君武[1] WU Biye;ZHAO Xihui;WU Yue;DAI Junwu(Key Laboratory of Earthquake Engineering and Engineering Vibration,Institute of Engineering Mechanics,China Earthquake Administration 29#Xuefu Road,Harbin,150080,China;Heilongjiang jiuzhou fangyuan architectural planning and design Co.,Ltd.,Harbin 150090,China;Heilongjiang Province Cold Region Constructure Science Research Institute,Harbin 150080,China;Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education,Harbin Institute of Technology,Harbin 150090,China;Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology,Harbin Institute of Technology,Harbin 150090,China)

机构地区:[1]中国地震局工程力学研究所,中国地震局地震工程与工程振动重点实验室,哈尔滨150080 [2]黑龙江省九州方圆建筑规划设计有限公司,哈尔滨150090 [3]黑龙江省寒地建筑科学研究院,哈尔滨150080 [4]哈尔滨工业大学,结构工程灾变与控制教育部重点实验室,哈尔滨150090 [5]哈尔滨工业大学,土木工程智能防灾减灾工业和信息化部重点实验室,哈尔滨150090

出  处:《低温建筑技术》2021年第6期66-70,共5页Low Temperature Architecture Technology

摘  要:加油站罩棚网架结构对于保障人民正常出行起到不可或缺的作用,近年东北地区因大面积降雪引起了多起加油站网架坍塌事故。文中以东三省近300座加油站罩棚网架安全性普查为契机,针对加油站罩棚网架结构特点,依据国家相关规范,提出系统性、规范性的检测鉴定方法,为类似工程检测鉴定提供宝贵经验。The gas station awning grids play an indispensable role in ensuring people’s normal travel. In recent years, many grids collapse accidents of gas stations were caused by large snowfall in Northeast China. Based on the safety survey of nearly 300 gas stations in the northeastern provinces, this paper proposes a systematic and normative detection and identificable method for the structure characteristics of the gas station grids and the relevant national standards, providing valuable experience for the detection and identification of similar projects.

关 键 词:加油站罩棚网架 安全隐患 强度检测 可靠性鉴定 

分 类 号:TU323.5[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象