Flood-illuminated adaptive optics ophthalmoscope with a single curved relay mirror  被引量:3

在线阅读下载全文

作  者:Ruixue Liu Yue Qi Xianliang Zheng Mingliang Xia Li Xuan 

机构地区:[1]State Key Laboratory of Applied Optics,Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun,Jilin 130033,China [2]University of Chinese Academy of Sciences,Beijing 100039,China [3]Jiangsu Key Laboratory of Medical Optics,Suzhou Institute of Biomedical Engineering and Technology,Chinese Academy of Sciences,Suzhou,Jiangsu 215163,China

出  处:《Photonics Research》2013年第3期124-129,共6页光子学研究(英文版)

基  金:the National Natural Science Foundation of China(Nos.60736042,1174274,and 1174279);the Plan for Scientific and Technology Development of Suzhou,China(No.ZXS201001).

摘  要:For decreasing light loss and diminishing the aberrations of the optical system,an open-loop adaptive optics(AO)system for retinal imaging in vivo is introduced.Taking advantage of the ability of young human eyes to accommodate,there was only one single curved mirror to make the pupil of the eye conjugate with the wavefront corrector and the wavefront sensor.A liquid crystal spatial light modulator(LC-SLM)was adopted as the wavefront corrector because the LC-SLM can be made in a small size to match the sensor.To reduce a pair of lenses or focusing mirrors,the wavefront corrector and sensor are positioned in the noncommon path.The system adopts open-loop control and the high-precision LC-SLM guarantees the effectiveness of the AO system.The designed field of view is 1°on the retina(about 300μm).The image quality was simulated with different mirror surface types,including circular,parabolic,and hyperbolic.A hyperbolic mirror with conic constant−1.07,which is close to−1,could best eliminate the aberrations.Theoretical analysis showed that the optical throughput of this system was at least 22.4%higher than that of a standard transmission AO system.In a practical experiment,a parabolic mirror was positioned in the optical path.Images of the cone photoreceptors and the capillary vessels were obtained successfully.This system simplifies the optical setup in comparison to the commonly used 4F systems while still guaranteeing the effectiveness of AO to correct the ocular aberrations.

关 键 词:MIRROR OPTICS curved 

分 类 号:O43[机械工程—光学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象