检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:彭涛 焦学诗玛 郑丕苗 梁展玮 熊进城 戴新华[1] PENG Tao;JIAO Xueshima;ZHENG Pimiao;LIANG Zhanwei;XIONG Jincheng;DAI Xinhua(National Institute of Metrology,Beijing 100029,China;China Jiliang University,Hangzhou 310018,China;China Agricultural University,Beijing 100193,China)
机构地区:[1]中国计量科学研究院,北京100029 [2]中国计量大学,杭州310018 [3]中国农业大学,北京100193
出 处:《计量科学与技术》2021年第5期40-45,共6页Metrology Science and Technology
基 金:中国计量科学研究院基本科研业务费(AKY1944,AKY1934);国家自然科学基金资助项目(31672600)。
摘 要:血清中谷胱甘肽(GSH)的含量水平与多种疾病的发生相关,本文成功建立了一种能快速灵敏测量GSH含量的荧光法。以二氧化硅纳米颗粒为载体和稳定剂,在超声条件下简单、快速地合成了二氧化锰包覆的二氧化硅纳米颗粒(SiO2@MnO2);以精氨酸和胸腺嘧啶为配体合成了具有高荧光量子产率的荧光金纳米簇(Arg/ATT/AuNCs)。实验结果表明GSH的强还原性可以分解MnO2释放出Mn(II)猝灭Arg/ATT/AuNCs的荧光,因此建立了基于SiO2@MnO2和Arg/ATT/AuNCs的荧光法测量血清中GSH。在最优条件下,该方法定量测量GSH的线性范围为2.5~20 nmol/L,最低检测限为1.23 nmol/L,优于已报道的类似方法。本方法测量低、中、高浓度GSH的相对扩展不确定度分别为8.6%、12.4%、18.8%(k=2),准确度在87.0%~105.6%之间,满足GSH检测的需求,为血清中GSH含量的灵敏、准确测量提供了新技术。The level of glutathione(GSH)in serum has been correlated with the occurrence of various diseases.In this paper,a fluorescence method that can measure GSH levels rapidly and sensitively was successfully established.In this method,manganese dioxide-coated silica nanoparticles(SiO2@MnO2)were synthesized simply and rapidly under ultrasonic conditions using silica nanoparticles as carriers and stabilizers,and fluorescent gold nanoclusters(Arg/ATT/AuNCs)with high fluorescence quantum yields were synthesized using arginine and thymine as ligands.The experimental results showed that the strong reduction of GSH could decompose MnO2 to release Mn(II)to burst the fluorescence of Arg/ATT/AuNCs,so a fluorescence method based on SiO2@MnO2 and Arg/ATT/AuNCs was established to measure GSH in serum.Under optimal conditions,the linear range of the method for quantitative measurement of GSH was from 2.5 to 20 nmol/L with a minimum detection limit of 1.23 nmol/L,which was better than similar methods that have been reported.The relative extended uncertainties of the method were 8.6%,12.4%,and 18.8%(k=2)for low,medium,and high GSH concentrations,respectively,with accuracies ranging from 87.0%to 105.6%,which meet the requirements of GSH determination and provide a new technique for sensitive and accurate measurement of GSH in serum.
关 键 词:谷胱甘肽 二氧化锰 荧光金纳米簇 荧光法 快速测量 纳米材料
分 类 号:R446[医药卫生—诊断学] TB383.1[医药卫生—临床医学] O657.3[一般工业技术—材料科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222