作 者:Yan Li Sucbei Moon Jason JChen Zhikai Zhu Zhongping Chen
机构地区:[1]Beckman Laser Institute,University of California,Irvine,Irvine,CA 92612,USA [2]Department of Biomedical Engineering,University of California,Irvine,Irvine,CA 92617,USA [3]Department of Physics,Kookmin University,Seoul 02707,South Korea
出 处:《Light(Science & Applications)》2020年第1期1470-1479,共10页光(科学与应用)(英文版)
基 金:National Institutes of Health(R01EY-026091,R01EY-028662,R01HL-125084,R01HL-127271);American Heart Association(18PRE34050021);the National Science Foundation(DGE-1839285).
摘 要:The phase stability of an optical coherence elastography(OCE)system is the key determining factor for achieving a precise elasticity measurement,and it can be affected by the signal-to-noise ratio(SNR),timing jitters in the signal acquisition process,and fluctuations in the optical path difference(OPD)between the sample and reference arms.In this study,we developed an OCE system based on swept-source optical coherence tomography(SS-OCT)with a common-path configuration(SS-OCECP).Our system has a phase stability of 4.2 mrad without external stabilization or extensive post-processing,such as averaging.This phase stability allows us to detect a displacement as small as~300 pm.A common-path interferometer was incorporated by integrating a 3-mm wedged window into the SS-OCT system to provide intrinsic compensation for polarization and dispersion mismatch,as well as to minimize phase fluctuations caused by the OPD variation.The wedged window generates two reference signals that produce two OCT images,allowing for averaging to improve the SNR.Furthermore,the electrical components are optimized to minimize the timing jitters and prevent edge collisions by adjusting the delays between the trigger,k-clock,and signal,utilizing a high-speed waveform digitizer,and incorporating a high-bandwidth balanced photodetector.We validated the SSOCECP performance in a tissue-mimicking phantom and an in vivo rabbit model,and the results demonstrated a significantly improved phase stability compared to that of the conventional SS-OCE.To the best of our knowledge,we demonstrated the first SS-OCECP system,which possesses high-phase stability and can be utilized to significantly improve the sensitivity of elastography.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.131.131