作 者:Ming-Da Zhou Muhammad Akbar Andrew J.Myrick Yiqiu Xia Waleed J.Khan Xiang Gao Thomas C.Baker Si-Yang Zheng
机构地区:[1]Micro&Nano Integrated Biosystem(MINIBio)Laboratory,Department of Biomedical Engineering,The Pennsylvania State University,University Park,PA 16802,USA [2]Materials Research Institute,The Pennsylvania State University,University Park,PA 16802,USA [3]Department of Entomology,The Pennsylvania State University,University Park,PA 16802,USA [4]Department of Electrical Engineering,The Pennsylvania State University,University Park,PA 16802,USA
出 处:《Microsystems & Nanoengineering》2017年第1期1-10,共10页微系统与纳米工程(英文)
基 金:We also thank DuPont for providing the polyimide membrane samples.This work was supported by the National Science Foundation under Grant Number DBI-1353870,which was offered to S-YZ and TCB.
摘 要:We report the design,fabrication and characterization of a microelectromechanical systems(MEMS)flow control device for gas chromatography(GC)with the capability of sustaining high-temperature environments.We further demonstrate the use of this new device in a novel MEMS chopper-modulated gas chromatography-electroantennography(MEMS-GC-EAG)system to identify specific volatile organic compounds(VOCs)at extremely low concentrations.The device integrates four pneumatically actuated microvalves constructed via thermocompression bonding of the polyimide membrane between two glass substrates with microstructures.The overall size of the device is 32 mm×32 mm,and it is packaged in a 50 mm×50 mm aluminum housing that provides access to the fluidic connections and allows thermal control.The characterization reveals that each microvalve in the flow control chip provides an ON to OFF ratio as high as 1000:1.The device can operate reliably for more than 1 million switching cycles at a working temperature of 300℃.Using the MEMS-GC-EAG system,we demonstrate the successful detection of cis-11-hexadecenal with a concentration as low as 1 pg at a demodulation frequency of 2 Hz by using an antenna harvested from the male Helicoverpa Virescens moth.In addition,1μg of a green leafy volatile(GLV)is barely detected using the conventional GC-EAG,while MEMS-GC-EAG can readily detect the same amount of GLV,with an improvement in the signal-to-noise ratio(SNR)of~22 times.We expect that the flow control device presented in this report will allow researchers to explore new applications and make new discoveries in entomology and other fields that require high-temperature flow control at the microscale.
关 键 词:ELECTROANTENNOGRAPHY gas chromatography MEMS flow control device MICROVALVE