作 者:范宋杰 魏勇[1] 余厚全[1] 刘建成 刘国权 崔炳超 FAN Song-jie;WEI Yong;YU Hou-quan;LIU Jian-cheng;LIU Guo-quan;CUI Bing-chao(Electronics & Information School, Yangtze University, Jingzhou 434023, China;Production Logging Company, China Petroleum Logging Co. Ltd., Xi’an 710077, China;Instrument Maintenance Equipment Center of Xinjiang Branch, China Petroleum Logging Co. Ltd., Karamay 834000, China)
机构地区:[1]长江大学电子信息学院,荆州434023 [2]中国石油集团测井有限公司生产测井公司,西安710077 [3]中国石油集团测井有限公司新疆分公司仪修装备中心,克拉玛依834000
出 处:《科学技术与工程》2021年第18期7513-7518,共6页Science Technology and Engineering
基 金:国家科技重大专项(2017ZX05019001)。
摘 要:针对目前中国低产液油井的流量测量需求,根据强迫对流换热的原理,提出了恒温差阵列式流量检测方法,设计了温差控制电路和6通道数字电源,开发了一款阵列恒温差热式流量计。在此基础上进行了相关实验,实验结果表明,该仪器对于1~15 m^(3)/d的流量检测分辨率达到了1 m^(3)/d,且仪器对流体流量变化反应灵敏,集成度高,体积小,性能稳定,因此对低产液水平井大斜度井井下流量的在线测量有重要的参考价值。As to the current demand of flow measurement in low yield production oil wells in China,according to the detection principal of forced convection heat transfer,a constant temperature difference array flow detection method was proposed.A temperature difference control circuit and six-channel digital power were designed and a constant temperature difference thermal flowmeter with array sensor were developed.On the basis above,relevant experiments were carried out and the experimental result shows that the flowmeter’s detection resolution can reach 1 m^(3)/d in the range of 1~15 m^(3)/d.In addition,the instrument is sensitive to the change of fluid flow,and has characteristics of high integration,small volume and stable performance.Therefore,it has significant reference value for real time fluid measurement in low liquid production horizontal wells and high deviated wells.
关 键 词:热式流量计 强迫对流换热 恒温差 低产液 高分辨率
分 类 号:TE352[石油与天然气工程—油气田开发工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171