Modes of failure with fractional flow reserve guidewires:Insights from the manufacturer and user facility device experience database  

在线阅读下载全文

作  者:Nauman Khalid Yagya Pandey Umair Khalid Hassan Kamran Jason P Wermers Lovely Chhabra Mahboob Alam Hani Jneid Waleed Tallat Kayani 

机构地区:[1]Department of Interventional Cardiology,St.Francis Medical Center,Monroe,LA 71201,United States [2]Department of Internal Medicine,Baylor College of Medicine,Houston,TX 77030,United States [3]Department of Interventional Cardiology,Michael E.DeBakey VA Medical Center,Houston,TX 77030,United States [4]Department of Interventional Cardiology,Baylor College of Medicine,Houston,TX 77030,United States [5]Health Sciences,University of Maryland Graduate School,Baltimore,MD 21201,United States

出  处:《World Journal of Cardiology》2021年第7期223-229,共7页世界心脏病学杂志(英文版)(电子版)

摘  要:BACKGROUND Fractional flow reserve(FFR)measurement is commonly used in the cardiac catheterization laboratory to assess the functional significance of coronary arterial plaques.Robust real-world data on complications and modes of failure of FFR guidewires are limited.AIM To characterize these outcomes by analyzing the post-marketing surveillance data from the United States Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database for commonly used FFR guidewires.METHODS The MAUDE database was queried from January 2010 through April 2020 for 3 FFR guidewires[PressureWireTM X(Abbott),CometTM(Boston Scientific),and VerrataTM(Philips)]by searching for the following events:“Injury”,“malfunction”,“death”,and“other”.This yielded 544 reports.After excluding incomplete reports,486 reports were analyzed.RESULTS Guidewire tip fracture was the most commonly reported mode of failure,in 174(35.8%)cases followed by guidewire kinking(n=152,31.3%),communication failure(n=141,29.0%),and shaft fracture(n=67,13.8%).In total,133(27.4%)device failures resulted in patient adverse events.The most common adverse event was retained guidewire tip,in 71(53.4%)cases,followed by freshly deployed stent dislodgment(n=26,19.6%)and coronary artery dissection(n=23,17.3%).Seven deaths were reported.CONCLUSION FFR guidewire failures can occur because of various mechanisms and cause patient adverse events.The MAUDE database serves as an important platform for improved collaboration among clinicians,device manufacturers,and regulators to improve device performance and optimize patient outcomes.Our analysis provides mechanistic insights of FFR guidewire failure and associated adverse events but cannot verify causality or provide a comparison among different guidewires.

关 键 词:Fractional flow reserve Coronary guidewire Adverse events Modes of failure Food and Drug Administration Manufacturer and user facility device experience 

分 类 号:R197.39[医药卫生—卫生事业管理]

 