检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周光辉[1] 白军琴 李海军[1] 苏之勇 韩闯 张中来 范月华 袁铁索 楚雪靖 Zhou Guanghui;Bai Junqin;Li Haijun;Su Zhiyong;Han Chuang;Zhang Zhonglai;Fan Yuehua;Yuan Tiesuo;Chu Xuejing(School of Energy and Environment,Zhongyuan Institute of Technology,Zhengzhou 450007,China;Henan Wanjia Construction Engineering Co.Ltd.,Zhengzhou 450007,China)
机构地区:[1]中原工学院能源与环境学院,郑州450007 [2]河南万佳建设工程有限公司,郑州450007
出 处:《低温与超导》2021年第7期53-58,102,共7页Cryogenics and Superconductivity
基 金:国家自然科学基金(51676201);河南省高等学校供热空调重点学科开放实验室研究基金(2017HAC201)资助。
摘 要:针对纯电动客车热泵空调系统制冷与制热性能衰减严重、耗能较高等问题,设计并搭建了一款基于R410A纯电动客车热泵空调系统实验台。该实验研究了变车外风机风量对热泵系统性能的影响。实验结果表明:低压补气制冷工况下:车内风量为100%,车外风量从40%增加到100%时,系统制冷量增加1.45%,COP1上升12.7%,COP2下降19.4%,压缩机功率下降11.1%,排气温度降低11%。制热工况下,系统制热量增加3.2%,COP1上升8.5%,COP2下降27.7%,压缩机功率下降29.5%,车内出风温度降低0.7%。Aiming at the serious attenuation of cooling and heating performance and high energy consumption of electric bus heat pump air conditioning system, an experimental platform based on R410 A electric bus heat pump air conditioning system was designed and built.The influence of variable fan volume on the performance of heat pump system was studied.The experimental results show that under the condition of low-pressure supplementary air refrigeration, when the interior air volume is 100% and the exterior air volume increases from 40% to 100%, the system cooling capacity increases by 1.45%, COP1 increases by 12.7%, COP2 decreases by 19.4%, compressor power decreases by 11.1%, and exhaust temperature decreases by 11%.Under the heating condition, the heat produced by the system increases by 3.3%, COP1 increases by 8.5%, COP2 decreases by 27.7%, compressor power decreases by 29.5%, and the air outlet temperature in the vehicle decreases by 0.7%.
分 类 号:TB657[一般工业技术—制冷工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222