作 者:梁远森 王宁[2,3] 季可凡 侯和涛 LIANG Yuansen;WANG Ning;JI Kefan;HOU Hetao(Zhengzhou Urban Construction Group Investment Co., Ltd., Zhengzhou 450001, P. R. China;School of Civil Engineering, Shandong University, Jinan 250061, P. R. China;Shandong Engineering & Technology Research Center for Green Building and Intelligent Construction, Jinan 250061, P. R. China)
机构地区:[1]郑州城建集团投资有限公司,郑州450001 [2]山东大学土建与水利学院,济南250061 [3]山东省绿色建筑智能建造工程技术研究中心,济南250061
出 处:《土木与环境工程学报(中英文)》2021年第5期101-111,共11页Journal of Civil and Environmental Engineering
基 金:国家自然科学基金(51878390)。
摘 要:将传统复合墙板平板层改为带肋层,优化截面的混凝土配置,从而降低复合墙板自重,在墙板两侧对称施加预应力筋,增强复合墙板的抗裂性能。为研究带肋预应力混凝土复合墙板的抗弯性能,进行了3个试件在均布力作用下的抗弯试验,分析该混凝土复合墙板的力学性能和变形模态。通过理论分析推导该混凝土复合墙板的抗弯承载力计算公式,采用ABAQUS软件进行该混凝土复合墙板的对比模拟,并对肋板角度参数进行模拟分析。结果表明:带肋预应力混凝土复合墙板与平板混凝土复合墙板存在近似的弯曲响应;带肋预应力混凝土复合墙板的抗弯承载力与平板混凝土复合墙板相比有所下降,但降幅小于自重降幅;预应力的施加显著提高了混凝土复合墙板的承载力和抗裂性能;提出的混凝土复合墙板的承载力计算公式、有限元模型均与试验结果吻合较好。The ribbed prestressed concrete composite wall panel changes the traditional composite wall panel layer into the ribbed layer,and optimizes the concrete configuration of the section to reduce the self-weight of the composite wall panel.Prestressed reinforcement is added to both sides of the wall panel,which can increase the crack resistance of composite wall panel.In order to study the bending performance of the concrete composite wall panels,the bending test of three specimens under uniform load was carried out,and the mechanical properties and deformation modes of the concrete composite wall panel were analyzed.The calculation formula of flexural bearing capacity was derived through theoretical analysis.The comparative simulation and ribbed plate angle parameter analysis of the composite wall panels were conducted by the finite element software ABAQUS.The results showed that the ribbed prestressed composite wall panel had similar bending behavior to the traditional composite wall panel.The flexural capacity of the ribbed prestressed composite wall panels decreased,but its reduction was less than the self-weight reduction.The application of prestressing could significantly improve the bearing capacity and crack resistance of the composite wall panel.The proposed calculation formula of the bearing capacity and the finite element simulation results of the ribbed prestressed composite wall panels were in good agreement with the experimental results.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15