烧成隧道窑冷却风机位置认识  被引量:1

Discussion on setting of cooling fan in tunnel kiln

在线阅读下载全文

作  者:陈荣生 刘宗云 CHEN Rong-sheng;LIU Zong-yun

机构地区:[1]贵州省建材科研设计院有限责任公司,贵州贵阳550007

出  处:《砖瓦》2021年第8期31-35,37,共6页Brick-tile

摘  要:分析了烧结砖内燃焙烧的特殊性,指出焙烧窑保温冷却带所需冷空气存在负压吸入、窑内出风口输入和窑门风机输入三种方式,三种方式各有特点,建议当采用风机输送冷空气时,在窑门上设置风机,可避免窑内气流分层,提高产量和质量。The article analyzes the particularity of the internal combustion and firing of fired bricks,and points out that there are three methods of negative pressure inhalation of the cold air required for the insulation and cooling zone of the tunnel kiln,input from the kiln outlet and input of the kiln fan.The three methods have their own characteristics and are recommended to be used.When the fan delivers cold air,install a fan on the kiln door to avoid stratification of airflow in the kiln and improve output and quality.

关 键 词:内燃焙烧 保温冷却带 冷却风机位置 负压吸入 

分 类 号:TU522.064[建筑科学—建筑技术科学]

 