可变频式电磁防垢除垢水处理装置设计和试验  被引量:2

Design and test of variable frequency electromagnetic anti-scale and descaling water treatment device

在线阅读下载全文

作  者:黄泽奇 张录社 张建国 张书勤 陈义哲 袁平[5] HUANG Zeqi;ZHANG Lushe;ZHANG Jianguo;ZHANG Shuqin;CHEN Yizhe;YUAN Ping(Dutway Petroleum Technology Co.,Ltd.,Chengdu,Sichuan 61000 China;Yanchang Petroleum Group Co.,Ltd.,Zichang Oil Production Plant,Yan’an,Shanxi 710000,China;Yanchang Petroleum(Group)Co.,Ltd.,Research Institute,Yan’an,Shanxi 710000,China;Zhengzhou University of Light Industry,Zhengzhou,Henan 450003,China;PetroChina Liaohe Oilfield Company,Panjin,Liaoning 124010,China)

机构地区:[1]成都杜特威石油科技有限公司,四川成都610000 [2]延长油田子长采油厂,陕西延安710000 [3]延长石油(集团)有限责任公司研究院,陕西延安710000 [4]郑州轻工业大学,河南郑州450003 [5]中国石油辽河油田分公司,辽宁盘锦124010

出  处:《世界石油工业》2021年第3期58-63,共6页World Petroleum Industry

基  金:国家重点研发专项“煤炭清洁高效利用和新型节能技术”(2018YFB0605500)。

摘  要:针对西北部油气田注水系统管道结垢及腐蚀问题,运用电磁水处理技术,结合磁场抑垢除垢理论和磁化水分子结构变化理论,通过研究变频电磁场对结垢、防垢的影响,设计了一种新型可变频式电磁防垢除垢水处理装置,并将研究成果应用于延长油田子长采油厂,通过挂片试验法对装置的实际应用效果进行对比分析。结果表明:当装置提供扫描时间周期为1.667 s、调制度及波形为半正弦波的磁场时,对Ca^(2+)、CO _(3)^(2−)、SO _(4)^(2−)等结垢离子的结垢形态诱导作用最大,且试验后管道结垢速率降低61.71%。该装置可调频率为1~40 kHz,适用范围广,有效减少了管道结垢腐蚀产生的经济损失及相关作业,对促进油田产能建设具有重要意义。Aiming at the problems of scale and corrosion of pipelines in the water injection system of the northwestern oil and gas fields,using electromagnetic water treatment technology,combining the theory of magnetic field fouling and descaling and the theory of magnetic water molecular structure change.By studying the influence of frequency conversion electromagnetic field on scaling and anti-scaling,a new type of frequency conversion electromagnetic anti-scale and descaling water treatment device was designed.Apply the research results to the Zichang Oil Production Plant of Yanchang Oilfield.The actual application effect of the device is compared and analyzed by the coupon test method.The results show that:when the device provides a magnetic field with a scanning time period of 1.667 s,a modulation degree and a waveform of 50%Sine.It has the greatest effect on inducing scale formation of scale ions such as Ca^(2+),CO_( 3)^(2−),and SO _(4)^(2−),and after the test,the fouling rate of the pipeline decreased by 61.71%.The adjustable frequency of the device is 1-40 kHz.It has a wide range of applications,effectively reducing the economic losses and related operations caused by pipeline fouling and corrosion.This research is of great significance to promote the construction of oilfield production capacity.

关 键 词:注水系统 磁场 现场可编程逻辑门阵列 晶体结构 结垢速率 

分 类 号:TE980[石油与天然气工程—石油机械设备]

 