基于实测的循环流化床锅炉空气预热器及烟气处理设施对SO_(3)脱除作用的研究  被引量:3

Research on SO_(3) Removal Effect of Air Preheater and Flue Gas Treatment Facility of Circulating Fluidized Bed Boiler Based on Actual Measurement

在线阅读下载全文

作  者:朱愉洁[1] 韩元[1] 张文平 沈建军[1] ZHU Yu-jie;HAN Yuan;ZHANG Wen-ping;SHEN Jian-jun(Inner Mongolia Electric Power Science&Research Institute,Hohhot,China,010020;Inner Mongolia Jingneng Shuangxin Co.Ltd.,Ordos,China,016062)

机构地区:[1]内蒙古电力科学研究院,内蒙古自治区呼和浩特010020 [2]内蒙古京能双欣发电有限公司,内蒙古自治区鄂尔多斯016062

出  处:《热能动力工程》2021年第7期81-86,共6页Journal of Engineering for Thermal Energy and Power

基  金:内蒙古电力科学研究院自筹科技项目(2019-ZC-06)。

摘  要:为了研究循环流化床锅炉(circulating fluidized bed boiler,CFB)的空气预热器和烟气处理设施对SO_(3)的脱除作用,利用控制冷凝法分别对装机容量在150~330 MW之间的10台循环流化床锅炉进行了实测。结果表明:空气预热器对SO_(3)的脱除率受空气预热器烟气出口温度的影响,在6.7%~36.5%之间,回转式空气预热器的SO_(3)脱除率高于管式空气预热器;布袋除尘器和电袋除尘器对SO_(3)的脱除率在40%以上;静电除尘器的SO_(3)脱除率在6.1%~10.8%之间;湿法脱硫的SO_(3)脱除率在41.7%~73.4%之间,其中双塔双循环的SO_(3)脱除率最高;炉外CFB半干法脱硫的SO_(3)脱除率达89.7%~97.9%,测试条件下炉内干法+炉外CFB半干法的工艺能使脱硫出口SO_(3)降至0.3 mg/m^(3)以下。In order to study the effect of the air preheater and flue gas treatment facility of circulating fluidized bed(CFB)boiler on the removal of SO_(3),the controlled condensing method was used to analyze 10 CFB boilers with installed capacity between 150 MW and 330 MW respectively.The results show that the removal rate of SO_(3)by the air preheater is affected by the outlet flue gas temperature,which is between 6.7%and 36.5%.The SO_(3)removal rate of the rotary air preheater is higher than that of the tubular air preheater.The SO_(3)removal rates of cloth bag precipitator and electric bag precipitator are more than 40%;the SO_(3)removal rate of electrostatic precipitator is between 6.1%and 10.8%.The SO_(3)removal rate of wet flue gas desulfurization(WFGD)is between 41.7%and 73.4%,among which the double tower and double circulation SO_(3)removal rate is the highest.The SO_(3)removal rate of CFB semi-dry desulfurization outside the furnace is between 89.7%and 97.9%.Under the test conditions,the process of furnace dry method with the addition of semi-dry method outside the furnace can reduce SO_(3)at the outlet of desulfurization to below 0.3 mg/m^(3).

关 键 词:循环流化床锅炉 SO_(3) 空气预热器 控制冷凝法 半干法脱硫 炉内脱硫 

分 类 号:X701.3[环境科学与工程—环境工程]

 