球囊辅助技术帮助指引导管通过桡动脉夹层段76例临床分析  

Clinical analysis of balloon-assisted tracking in guiding tube through radial artery dissection in 76 cases

在线阅读下载全文

作  者:韦恒[1] 巫相宏[1] 朱海[2] 马国添 张小新 黄锡明 欧传杰[5] 赖美声 赵英艺 Wei Heng;Wu Xianghong;Zhu Hai;Ma Guotian;Zhang Xiaoxin;Huang Ximing;Ou Chuanjie;Lai Meisheng;Zhao Yingyi(Institute of Cardiovascular Disease,The First Affiliated Hospital of Guangxi Medical University,Nanning 530021,China;Department of Cardiology,The People’s Hospital of Beihai,Beihai 536000,China;Department of Cardiology,Kaiyuan Langdong Hospital of Guangxi Medical University,Nanning 530021,China;Department of Cardiology,The People’s Hospital of Hezhou,Hezhou 542800,China;Department of Cardiology,The People’s Hospital of Pingnan County,Pingnan 537300,China;Department of Cardiology,The People’s Hospital of Hepu County,Hepu 536100,China;Department of Cardiology,The People’s Hospital of Pubei County,Pubei 535300,China)

机构地区:[1]广西医科大学第一附属医院心血管病研究所,南宁530021 [2]北海市人民医院心内科,北海536000 [3]广西医大开元琅东医院心内科,南宁530021 [4]贺州市人民医院心内科,贺州542800 [5]平南县人民医院心内科,平南537300 [6]合浦县人民医院心内科,合浦536100 [7]浦北县人民医院心内科,浦北535300

出  处:《广西医科大学学报》2021年第8期1586-1589,共4页Journal of Guangxi Medical University

摘  要:目的:探讨应用球囊辅助技术帮助指引导管通过桡动脉夹层段的可行性和安全性。方法:回顾性分析2016年1月至2019年12月在广西医科大学第一附属医院等7家医院住院治疗的76例冠心病患者在经桡动脉路径行冠状动脉介入过程中发生桡动脉损伤引起夹层时,应用球囊辅助技术帮助指引导管通过夹层段的成功率、手术并发症和预后情况。结果:74例行冠状动脉介入治疗患者的指引导管能顺利通过桡动脉夹层段,2例患者因导丝进入假腔未成功,成功率为97.4%;手术过程需要平均耗时约3 min左右;住院期间无严重出血并发症和支架内血栓事件发生。结论:经桡动脉路径行冠状动脉介入发生血管损伤夹层时应用球囊辅助技术可安全有效地帮助指引导管通过血管损伤夹层段并继续行冠状动脉介入治疗。Objective:To explore the feasibility and safety of a guide catheter passing through radial artery dissection during percutaneous coronary intervention(PCI)via radial artery access by the aid of balloon-assisted tracking(BAT).Methods:The clinical data of 76 patients with coronary artery disease undergoing PCI via radial artery access with radial artery dissection were retrospectively analyzed.Results:Guiding catheters of 74 patients were delivered through the dissection vessels successfully by the aid of BAT,but 2 patients had failed deliveries.The success rate was 97.4%.The passing time of BAT was approximately 3 minutes.No serious bleeding complications and stent thrombosis occurred during hospitalization.Conclusion:It was safe and feasible for passing the guiding catheter through the dissection vessels during PCI via radial artery access by the aid of balloon-assisted tracking.

关 键 词:经桡动脉路径介入治疗 桡动脉夹层 导丝 球囊 

分 类 号:R541.4[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象