内镜专用吸氧口垫的设计及应用  被引量:3

Design and clinical application of a special oxygen mouth guard for endoscopy

在线阅读下载全文

作  者:高秀珍 韩丽君[2] 张诚 倪燕丽[3] 尤永梅 陈益清[1] 杨玲玲 刘伟[3] 朱胜军 王怡君[3] 杨玉龙 何川崎 GAO Xiuzhen;HAN Lijun;ZHANG Cheng;NI Yanli;YOU Yongmei;CHEN Yiqing;YANG Lingling;LIU Wei;ZHU Shengjun;WANG Yijun;YANG Yulong;HE Chuanqi

机构地区:[1]同济大学附属东方医院消化内科,上海市200120 [2]同济大学附属东方医院胆石病中心,上海市200120 [3]同济大学附属东方医院内镜中心,上海市200120

出  处:《中华护理杂志》2021年第8期1272-1275,共4页Chinese Journal of Nursing

摘  要:目的设计内镜专用吸氧口垫,评价其临床应用效果。方法设计的内镜专用吸氧口垫包括口垫、鼻吸氧管、口腔吸氧管等7个部件。便利选取2021年1月—2月上海市某三级甲等医院内镜中心收治的120例因胆总管结石行内镜逆行胰胆管造影术的患者作为研究对象,采用随机数字表法分为试验组和对照组,每组各60例。试验组使用内镜专用吸氧口垫,对照组使用普通吸氧管及口垫。比较两组口垫佩戴时间、SpO_(2)波动差值、鼻导管移位率及医护人员满意度。结果试验组口垫佩戴时间为(20.58±2.43)s,对照组为(27.30±2.89)s,两组比较,差异具有统计学意义(t=-13.795,P<0.001);试验组SpO_(2)波动差值为2.00%(1.00%,2.75%),对照组为3.00%(2.00%,4.00%),两组比较,差异具有统计学意义(Z=-4.332,P<0.001);试验组鼻导管移位率为0,对照组为18.33%,两组比较,差异具有统计学意义(χ^(2)=-12.110,P=0.001);试验组医护人员满意度得分为(28.35±1.39)分,对照组为(26.48±1.56)分,两组比较,差异具有统计学意义(t=6.933,P<0.001)。结论内镜专用吸氧口垫佩戴方便,能减少患者术中SpO_(2)波动,降低鼻导管移位率,提高医护人员满意度及手术安全性。Objective To design a special oxygen mouth guard for endoscopy and to evaluate its clinical application effects.Methods The designed special oxygen mouth guard comprises 7 elements(such as mouth pad,nasal and oral oxygen inhalation tubes).A total of 120 patients with common bile duct stones undergoing endoscopic retrograde cholangiopancreatography at the endoscopy center of a tertiary hospital in Shanghai from January to February 2021 were included,and they were randomly divided into an experimental group and a control group,with 60 patients in each group.In the experimental group,the special oxygen mouth guard was used.In the control group,traditional oxygen tube and mouth guard were used.The wearing time,oxygen saturation(SpO_(2))fluctuations,nasal catheter displacement rate and medical staff satisfaction were evaluated and compared between 2 groups.Results The wearing time in the experimental group was(20.58±2.43)s,while it was(27.30±2.89)s in the control group,and the difference was statistically significant(t=-13.795,P<0.001).The SpO_(2) value in the experimental group was 2.00%(1.00%,2.75%),while it was 3.00%(2.00%,4.00%)in the control group,and the difference was statistically significant(Z=-4.332,P<0.001).The nasal catheter displacement rate in the experimental group was 0,while it was 18.33% in the control group,and the difference was statistically significant(χ^(2)=-12.110,P=0.001).The score of medical staff satisfaction in the experimental group was(28.35±1.39),while it was(26.48±1.56)in the control group,and the difference was statistically significant(t=6.933,P<0.001).Conclusion The special oxygen mouth guard for endoscopy is easy to wear,and it can reduce the fluctuations in SpO_(2) and nasal catheter displacement rate,and improve the medical staff satisfaction and safety of ERCP.

关 键 词:胰胆管造影术 内窥镜逆行 吸氧管 口垫 围手术期护理 

分 类 号:R472[医药卫生—护理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象