摘  要:报道1例输尿管皮肤造口患者更换双J管后出现的严重并发症。在斑马导丝引导下将双J管置入回肠,导致输尿管回肠瘘。提示当输尿管出现扭曲、狭窄以及炎症时,输尿管腔内不规范的操作导致输尿管穿孔的风险较高。规范化诊治以及合适的导丝选择可以降低输尿管穿孔的风险。A case of severe complications is presented that replaced the double J tubeless misguided by zebra guidewire into ileum in a patient with ureteral dermostomy,causing a ureteral ileum fistula.The result suggests improper operation of zebra guidewire could have a risk of ureteral perforation when the ureter is distorted,narrow or with inflammatory lesions.Standardized diagnosis and treatment and correct selection of guidewire can reduce the risk of ureteral perforation.

关 键 词:导管插入术 双J管 斑马导丝 输尿管穿孔 输尿管肠瘘 