检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Imran Ali Lakhiar Xingda Liu Guanqun Wang Jianmin Gao
机构地区:[1]School of Agricultural Equipment Engineering,Jiangsu University,Zhenjiang 212013,Jiangsu,China
出 处:《International Journal of Agricultural and Biological Engineering》2018年第5期59-64,共6页国际农业与生物工程学报(英文)
基 金:This work is financially supported by Jiangsu Province Agricultural independent innovation funds(CX(18)3048);the National Natural Science Foundation of China Program(No.51275214);the National Key Research and Development Program of China(Grant No.2017YFD0700101);the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(No.37(2014)).
摘 要:The objectives of this research were to reveal how main working parameters of ultrasonic atomizers would influence key properties of the atomized nutrient solution in an aeroponics system.The Yamazaki tomato nutrient solution was selected as a nutrient example.Uniform design(UD)method U_(12)(12^(2)×13)was adopted to arrange the test.In this test,spraying time and interval time were taken as quantitative factors with 12 levels(10,20,30,40,50,60,70,80,90,100,110,and 120 min,respectively),and ultrasonic atomizer frequency was taken as qualitative factor with 3 conditions(28 kHz,107 kHz,1.7 MHz).Based on test data,two regression formulations used to predict the values ofΔEC,andΔpH of atomized Yamazaki tomato nutrient solution was established and inspected.The spraying interval time of ultrasonic atomizers had no significant effect on EC and pH of the atomized Yamazaki tomato nutrient solution;the ultrasonic atomizer frequency was more effective than spraying time on the values of EC and pH;the values of EC and pH became maximum at(f_(3),T_(1))=(1.7 MHz,120 min)and minimum at(f_(1),T_(1))=(28 kHz,10 min).It was concluded that the effect of high-frequency(1.7 MHz)ultrasonic atomizer on EC and pH of the Yamazaki tomato nutrient solution was beyond the standard value for tomato growth.Therefore,the high-frequency(1.7 MHz)ultrasonic atomizer is not suitable for aeroponics cultivation when using the Yamazaki tomato nutrient solution as aeroponics nutrient solution.
关 键 词:AEROPONICS tomato nutrient solution EC PH ultrasonic atomizer frequency spray time interval time uniform design
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15