Experimental study of ultrasonic atomizer effects on values of EC and pH of nutrient solution  被引量:3

在线阅读下载全文

作  者:Imran Ali Lakhiar Xingda Liu Guanqun Wang Jianmin Gao 

机构地区:[1]School of Agricultural Equipment Engineering,Jiangsu University,Zhenjiang 212013,Jiangsu,China

出  处:《International Journal of Agricultural and Biological Engineering》2018年第5期59-64,共6页国际农业与生物工程学报(英文)

基  金:This work is financially supported by Jiangsu Province Agricultural independent innovation funds(CX(18)3048);the National Natural Science Foundation of China Program(No.51275214);the National Key Research and Development Program of China(Grant No.2017YFD0700101);the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(No.37(2014)).

摘  要:The objectives of this research were to reveal how main working parameters of ultrasonic atomizers would influence key properties of the atomized nutrient solution in an aeroponics system.The Yamazaki tomato nutrient solution was selected as a nutrient example.Uniform design(UD)method U_(12)(12^(2)×13)was adopted to arrange the test.In this test,spraying time and interval time were taken as quantitative factors with 12 levels(10,20,30,40,50,60,70,80,90,100,110,and 120 min,respectively),and ultrasonic atomizer frequency was taken as qualitative factor with 3 conditions(28 kHz,107 kHz,1.7 MHz).Based on test data,two regression formulations used to predict the values ofΔEC,andΔpH of atomized Yamazaki tomato nutrient solution was established and inspected.The spraying interval time of ultrasonic atomizers had no significant effect on EC and pH of the atomized Yamazaki tomato nutrient solution;the ultrasonic atomizer frequency was more effective than spraying time on the values of EC and pH;the values of EC and pH became maximum at(f_(3),T_(1))=(1.7 MHz,120 min)and minimum at(f_(1),T_(1))=(28 kHz,10 min).It was concluded that the effect of high-frequency(1.7 MHz)ultrasonic atomizer on EC and pH of the Yamazaki tomato nutrient solution was beyond the standard value for tomato growth.Therefore,the high-frequency(1.7 MHz)ultrasonic atomizer is not suitable for aeroponics cultivation when using the Yamazaki tomato nutrient solution as aeroponics nutrient solution.

关 键 词:AEROPONICS tomato nutrient solution EC PH ultrasonic atomizer frequency spray time interval time uniform design 

分 类 号:S64[农业科学—蔬菜学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象