作 者:Bing Zou Albert J.Heber Zhengxiang Shi Songhuai Du Yaomin Jin Teng Teeh Lim
机构地区:[1]College of Information and Electrical Engineering,China Agricultural University,Beijing 100083 China [2]Department of Agriculture and Biological Engineering,Purdue University,West Lafayette 47907,USA [3]College of Water Sources and Civil Engineering,China Agricultural University,Beijing 100083,China [4]Ministry of Energy,Mines and Petroleum Resources,Victoria V8W 9N3,Canada [5]College of Agriculture,Food and Natural Resources,University of Missouri,Columbia 65211,USA
出 处:《International Journal of Agricultural and Biological Engineering》2020年第6期41-46,共6页国际农业与生物工程学报(英文)
摘 要:Reliable estimation of the ventilation rate(VR)in intensive livestock buildings is necessary for studying building environmental control strategies and predicting indoor air quality and air emissions.As direct air exchange measurements are time-consuming and expensive,it is environmentally inefficient to measure livestock building VR continuously in practice.Hence,indirect VR estimation methods have been widely used in modelling environmental control and air emissions,and also to measure airflow in the field.The accuracy of indirect measurement methods needs to be evaluated by comparing with direct measurements.In this study,the direct and indirect methods of determining hourly and daily mean VRs were applied to a mechanically-ventilated dairy free stall barn monitored by the 24-month National Air Emissions Monitoring Study.The direct method was used to continuously monitor fan rotational speeds,and differential static pressures,coupled with periodic in-situ fan performance assessments,to calculate the VR.The indirect method consisted of estimating the VR using CO2 concentration measurements and the CO2 mass balance method.The average daily and hourly means(mean±SD)of directly measured barn ventilation rates for two years were(246±73)m3/s and(245±77)m3/s,respectively.The average daily and hourly means(mean±SD)of barn ventilation rates estimated by the CO2 mass balance method were(287±93.4)m3/s and(287±118)m3/s,respectively.Correlation analyses showed a strong correlation between the indirect CO2 mass balance method and direct measurement methods(r=0.93 for daily means and r=0.85 for hourly means).
关 键 词:dynamic ventilation rate modern dairy free stall barn carbon dioxide mass balance dairy cow direct and indirect determination comparison
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222