检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:段留省[1] 周天华[1] 苏明周[2] 潘宏 DUAN Liusheng;ZHOU Tianhua;SU Mingzhou;PAN Hong(School of Civil Engineering,Chang'an University,Xi'an 710061,China;School of Civil Engineering,Xi'an University of Architecture and Technology,Xi'an 710055,China;Western Construction Seismic Investigation,Design&Research Institute,Xi'an 710054,China)
机构地区:[1]长安大学建筑工程学院,陕西西安710061 [2]西安建筑科技大学土木工程学院,陕西西安710055 [3]西部建筑抗震勘察设计研究院,陕西西安710054
出 处:《建筑结构学报》2021年第9期44-51,共8页Journal of Building Structures
基 金:国家自然科学基金项目(51708038);陕西省重点研发计划(2016KTZDSF04-06);中央高校基本科研业务费专项(300102281504)。
摘 要:为解决现有单边螺栓容易拔出、钢管柱壁板撕裂等锚固不足问题,提出高强钢板-螺栓组合连接副,用于钢管柱框架节点。为研究该类节点的抗震性能和破坏模式,设计4个足尺比例的高强钢芯筒-螺栓连接钢管柱框架节点试件,变化参数为螺栓规格和钢梁端板厚度,分别进行单调加载静力试验和循环加载拟静力试验,考察节点破坏模式、转动能力、连接系数、耗能能力及螺栓拉力。研究表明:M20-20、M24-25两种钢板螺栓组合连接节点可达到抗震规范的节点承载力连接系数限值要求,为半刚性节点;单调和循环两种加载方式下节点的破坏模式相近,节点域应变和变形都较小,对节点转动角度影响可以忽略;循环加载下节点的破坏位移明显较单调加载的小,梁端受弯承载力略有提高,芯筒端部钢管柱应变显著增长,M24-25节点的耗能能力较M20-20的高约10%;循环荷载作用下的螺栓最大实测拉力大于单调荷载作用下的螺栓最大拉力,组合连接副承载力的设计方法有待进一步研究。In order to solve the insufficient anchorage problem of the blind bolt, such as the pulling out of blind bolt and the tearing of steel tube column corner plate, the high strength steel plate-bolt combined connection assemblies for steel tube column frame joint were proposed. To study the seismic behavior and the failure modes of the new frame joints, four 1∶1 full scaled high strength steel tube-bolt steel pipe column frame joint specimens were designed. The parameters studied included bolt specification and end plate thickness. The monotonic and cyclic tests were conducted respectively. The failure mode, rotation capacity, connection coefficient, energy dissipation capacity and bolt tension of the joint were studied. The research shows that both M20-20 and M24-25 bolts meet the connection coefficient requirement of the ultimate capacity in Chinese seismic code. All the specimens are semi-rigid joints. The failure modes under the monotonic test are similar to those of the cyclic test. In the joint panel zone, the strain and deformation are both small, where the rotation can be ignored for the joint rotation. For the cyclic and monotonic tests, the failure displacement of the former is smaller than that of the latter, and the ultimate bearing capacity is a little bigger than that of the latter, and the strain of column at the steel tube end increases rapidly under the cyclic loading. The energy dissipation capacity of the M24-25 assembled joint is about 10% higher than that of the M20-20. The maximum bolt tension tested under the cyclic loading is bigger than that under monotonic loading. The design method of bearing capacity for the high strength steel plate-bolt assemblies need to be further studied.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171