催化分馏塔在线水洗除盐技术应用总结  被引量:3

Application summary of online water washing desalination technologyfor catalytic fractionator

在线阅读下载全文

作  者:杨开研 张盼 Yang Kaiyan;Zhang Pan(Shaanxi Yanchang Petroleum(Group)Co.,Ltd.,Yan’an,Shaanxi 727406)

机构地区:[1]陕西延长石油(集团)有限责任公司,陕西省延安市727406

出  处:《炼油技术与工程》2021年第8期48-52,共5页Petroleum Refinery Engineering

摘  要:延安炼油厂2.0 Mt/a重油催化裂化装置自投产以来,先后多次出现分馏塔塔盘、空气冷却器、机泵、油气管线、换热器等堵塞和腐蚀泄漏问题,严重影响装置安全运行。为解决结盐腐蚀问题,采用了加缓蚀剂、在线水洗、加大水洗水用量等常规处理措施,取得了一定的效果。2020年对分馏塔塔顶循环回流系统实施了在线除盐技术改造,采用湍旋混合-顺流萃取-油水深度分离的组合方法,注水萃取分馏塔塔顶循环油中的腐蚀性介质和可溶性盐类,投用后分馏塔塔顶循环油氯离子质量分数稳定在2μg/g以下,分馏塔塔顶循环系统氯离子分离脱除率达到了80%左右,除盐效果明显。Since the 2.0 Mt/a heavy oil FCC unit in Yan’an Refinery was put into operation,the blockage and corrosion leakage of trays in the fractionator,air cooling exchanger,pump,oil and gas pipeline,heat exchanger and other problems occurred for many times,which seriously affected the safe operation of the unit.Some common measures for corrosion inhibition,such as adding corrosion inhibitor,online water washing,increasing washing water quantity had been adopted to solve the problem of salt corrosion,which had contributed to stable operation of the unit.In 2020,the combined method of turbulent mixing,downstream extraction and deep separation of oil and water was adopted to carry out on-line desalting technical transformation for the circulating reflux system at the top of fractionator.The corrosive medium and soluble salt in top circulation oil were extracted by water injection.The mass fraction of chlorine ion in the oil from the top circulation system could be decreased to less than 2μg/g and the removal rate of chlorine ion was reached 80%.The desalting effect was obvious.

关 键 词:催化分馏塔 在线水洗除盐 湍旋混合 分馏塔塔顶循环 油水深度分离 

分 类 号:TE962[石油与天然气工程—石油机械设备]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象