检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:高永强 弓海霞 GAO Yong-qiang;GONG Hai-xia(Wuxi Vocational College of Science and Technology,Wuxi 214028,China;Harbin Engineering University,Harbin 150001,China)
机构地区:[1]无锡科技职业学院,江苏无锡214028 [2]哈尔滨工程大学,黑龙江哈尔滨150001
出 处:《仪表技术与传感器》2021年第9期63-66,73,共5页Instrument Technique and Sensor
摘 要:精确测量光固化成型设备中光敏树脂的液面位置是确保成型精度的关键,根据激光三角法原理设计基于PSD的液位检测系统,采用点激光和一维位置敏感器件组成液位检测系统。通过测量点激光在PSD上的位移量来获取液面位置的变化量,在分析PSD误差特点基础上,通过优化结构设计、信号采集、检测系统标定和实时数据处理4个方面来提高检测精度。实际测试表明:液位检测系统量程中间位置的误差小于0.27%,两边误差小于0.4%,可满足系统测量精度要求。Precisely measurement of the resin liquid level of stereolithographic apparatus was the key to ensure the forming accuracy.According to the principle of laser triangulation method,the liquid level detection system was designed.The liquid level detection system was composed of point laser and one-dimensional position sensitive detector.The change of the liquid level position was obtained by measuring the displacement of the laser on the PSD.On the basis of analysis the PSD s error characteristics,four aspects were optimized to improve the measurement accuracy,including structure design,signal acquisition,calibration of detection system and real-time data processing.The result shows that the error of the middle position of the range of the liquid level detection system is less than 0.27%,and the error of both sides is less than 0.4%,which meets the requirements of system measurement accuracy.
关 键 词:光固化 位置敏感器件 液位检测 积分放大器 分段滤波
分 类 号:TN249[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30