检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:蒋培培 刘晓林[1] 王高峰 孙西振 陈永玲 JIANG Pei-pei;LIU Xiao-lin;WANG Gao-feng;SUN Xi-zhen;CHEN Yong-ling(Department of Central Functional,Fuyang People's Hospital,Fuyang 234000,China)
机构地区:[1]阜阳市人民医院中心功能科,安徽阜阳236000
出 处:《武警后勤学院学报(医学版)》2021年第8期47-49,共3页Journal of Logistics University of PAP(Medical Sciences)
摘 要:【目的】对比动态心电图与常规心电图检查在诊断房颤伴Ⅱ度房室传导阻滞中的临床价值。【方法】选取2019年1月至2020年10月90例在我科检查为房颤的患者作为研究对象,根据随机数字表法将分为研究组与对照组,各45例。两组患者分别实施动态心电图检查与常规心电图检查,对两组患者的诊断阳性率、R-R间隔时间以及心室率进行对比分析。【结果】研究组患者疾病诊断准确率、R-R间隔时间均显著高于对照组,研究组患者心室率明显低于对照组(P<0.05)。【结论】动态心电图在房颤伴Ⅱ度房室传导阻滞患者临床诊断中应用具有显著效果。【Objective】To observe and compare the clinical value of dynamic electrocardiogram and routine electrocardiogram in the diagnosis of atrial fibrillation with degree Ⅱ atrioventricular block.【Methods】A total of 90 patients with atrial fibrillation examined in our department from January 2019 to October 2020 were selected as the research object.According to the random number table method,the patients were divided into the research group and the control group,with 45 cases in each group.The patients in the two groups underwent dynamic electrocardiogram and routine electrocardiogram respectively.The diagnostic positive rate,R-R interval and ventricular rate of the two groups were compared and analyzed.【Results】The accuracy of disease diagnosis and R-R interval in the research group were significantly higher than those in the control group(P<0.05),and the ventricular rate in the research group was significantly lower than that in the control group(P<0.05).【Conclusion】Dynamic electrocardiogram has significant effect in clinical diagnosis of atrial fibrillation with degree Ⅱ atrioventricular block.
关 键 词:动态心电图 常规心电图 房颤 Ⅱ度房室传导阻滞 诊断
分 类 号:R541.7[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171