摘  要:在为客户提供技术服务的过程中发现,很多客户反映其检测的水泥强度总是比我公司检测的水泥强度偏低3~5MPa左右。经分析发现,影响水泥强度检测的结果的因素主要包括标准砂的质量、水泥试体的养护条件、抗压夹具的性能指标等三方面。水泥强度检测应严格按照国家规范进行,以确保检测结果的真实准确。In the process of providing technical services to our customers,many customers give the feedback that the measured strength of the cement tested was always about 3~5MPa lower than that of the cement tested by our company itself.According to the analysis,it is found that the factors affecting the test result of cement strength mainly include the quality of standard sand,the curing condition of cement test sample and the performance index of compression fixture.The cement strength testing should be carried out in strict accordance with national standards to ensure the authenticity and accuracy of the testing results.