机构地区:[1]Federal Agency for Occupational Risks,Avenue de l’Astronomie,1,B-1210,Bruxelles,Brussels,Belgium [2]Institute of Neurosciences,University of Louvain,Pasteur,Avenue Mounier,53,B-1200,Bruxelles,Brussels,Belgium
出 处:《Journal of Otology》2021年第4期242-251,共10页中华耳科学杂志(英文版)
摘 要:Objective: To define difference scores between PTA, ASSR and CERA thresholds in subjects with occupational NIHL.Design: 44 subjects undergoing a medico-legal expert assessment for occupational NIHL and fulfillingcriteria of reliability were considered. Assessment included: PTA, 40 Hz binaural multiple ASSR and CERA(1-2-3 kHz).Results: The respective average difference scores (ASSR - PTA) for 1, 2 and 3 kHz are 13.01 (SD 10.19) dB,12.72 (SD 8.81) dB and 10.38 (SD 8.19) dB. The average (CERA - ASSR) difference scores are 1.25 (SD 14.63)dB for 1 kHz (NS), 2.73 (SD 13.03) dB for 2 kHz (NS) and 4.51 (SD 12.18) dB for 3 kHz. The correlationbetween PTA and ASSR (0.82) is significantly stronger than that between PTA and CERA (0.71). In a givensubject, PTA thresholds are nearly always lower (i.e., better) than ASSR thresholds, whatever the frequency (1-2-3 kHz) and the side (right e left). A significant negative correlation is found between thedifference score (ASSR e PTA) and the degree of hearing loss.Conclusion: ASSR outperforms CERA in a medicolegal context, although overestimating the behavioralthresholds by 10e13 dB.
关 键 词:CERA ASSR NIHL Hearing thresholds OCCUPATIONAL
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.26