检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Jing-Fang Zhang Yin-Hui Du Hai-Yan Hu Xiu-Qing Han
机构地区:[1]Ultrasonic Department,The Second Affiliated Hospital of Xi'an Medical College,Xi’an 710038,Shaanxi Province,China [2]Ultrasonic Department,Xi’an Fifth Hospital Shanxi Provincial Hospital of Integrated Traditional Chinese and Western Medicine,Xi'an 710082,Shaanxi Province,China
出 处:《World Journal of Clinical Cases》2021年第28期8366-8373,共8页世界临床病例杂志
摘 要:BACKGROUND Coronary heart disease(CHD)causes many adverse cardiovascular events and poses a threat to the patient’s health and quality of life.AIM To evaluate ultrasonography for evaluation of cardiac function and lesion degree in patients with CHD.METHODS A total of 106 patients with CHD(study group)and 106 healthy individuals(control group)in our hospital from March 2019 to September 2020 were selected for this study.All subjects were examined by ultrasound,and the mitral orifice’s early-to-late diastolic blood flow velocity ratio(E/A),left ventricular end-diastolic volume(LVDd),and left atrial diameter(LAD)were measured.Values were compared between the study group and healthy group,and the correlation between the ultrasonic parameters of patients with different cardiac function grades and the degree of CHD were assessed.In addition,the ultrasonic parameters of patients with different prognoses were compared after a follow-up for 6 mo.RESULTS E/A(1.46±0.34)of the study group was smaller than that of the control group(1.88±0.44),while LVDd(58.24±5.05 mm)and LAD(43.31±4.38 mm)were larger(48.15±3.93 and 34.94±2.81,respectively;P<0.05).E/A for patients with grade III disease(1.41±0.43)was smaller and their LVDd(60.04±4.21 mm)and LA(44.16±2.79 mm)were larger than those in patients with grade II disease(1.71±0.48,52.18±3.67 mm,and 39.68±2.37,respectively;P<0.05).Patients with grade IV disease had smaller E/A(1.08±0.39)and larger LVDd(66.81±5.39 mm)and LAD(48.81±3.95 mm)than patients with grade II and III disease(P<0.05).In patients with moderate disease,E/A(1.44±0.41)was smaller and LVDd(59.95±4.14 mm)and LAD(45.15±2.97 mm)were larger than in patients with mild disease(1.69±0.50,51.97±3.88 and 38.81±2.56 mm,respectively;P<0.05).In patients with severe disease,E/A(1.13±0.36)was smaller and LVDd(67.70±6.11 mm)and LAD(49.09±4.05 mm)were larger than in patients with moderate disease(P<0.05).E/A was negatively correlated with cardiac function classi-fication and disease severity,while LVDd and
关 键 词:ULTRASONOGRAPHY Left ventricular end-diastolic volume Left atrial diameter Coronary heart disease Cardiac function
分 类 号:R541.4[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3