剪切波弹性成像评估脑卒中后下肢痉挛偏瘫患者跟腱硬度的研究  

Study on evaluation of Achilles tendon hardness in patients with spasticity and hemiplegia of lower limbs after stroke by shear wave elastography

在线阅读下载全文

作  者:阮坚[1] 潘永寿[1] 皮永前[1] 路海燕 舒真祥 RUAN Jian;PAN Yongshou;PI Yongqian;LU Haiyan;SHU Zhenxiang(Ultrasound Department,Liutie Central Hospital of Liuzhou City,Liuzhou 545007,Guangxi,China;Rehabilitation Department,Liutie Central Hospital of Liuzhou City,Liuzhou 545007,Guangxi,China)

机构地区:[1]广西柳州市柳铁中心医院超声科,广西柳州545007 [2]广西柳州市柳铁中心医院康复科,广西柳州545007

出  处:《右江医学》2021年第9期683-686,共4页Chinese Youjiang Medical Journal

基  金:广西卫生健康委员会自筹经费课题(Z20190341)。

摘  要:目的探讨剪切波弹性成像(SWE)量化评估脑卒中后下肢痉挛偏瘫患者跟腱(AT)硬度的可行性。方法选择2019年3月~2020年10月接受康复治疗的30例脑卒中后下肢痉挛偏瘫患者,患侧为病例组,健侧为对照组。利用灰阶超声及SWE技术分别测量并记录治疗前健患两侧及治疗3周后患侧AT的厚度及最大杨氏模量值,对结果进行统计学分析。结果30例患者治疗前患侧AT的最大杨氏模量值高于健侧,治疗3周后患侧AT的最大杨氏模量值较治疗前降低,差异有统计学意义(均P<0.001)。而治疗前健患侧以及治疗3周后患侧AT的厚度之间比较,差异无统计学意义(均P>0.05)。Pearson相关性分析显示30例患者治疗前、治疗3周后患侧AT最大杨氏模量值与其AT厚度均无明显相关性(r=0.240、r=0.167,均P>0.05)。结论SWE技术能够定量评估脑卒中患者跟腱弹性硬度的变化,为临床提供跟腱量化指标,指导康复治疗。Objective To explore the feasibility of shear wave elastography(SWE)in quantitative evaluation of the hardness of the Achilles tendon(AT)in patients with hemiplegia of lower limbs after stroke.Methods 30 patients with spastic hemiplegia of lower limbs after stroke who received rehabilitation treatment from March 2019 to October 2020 were selected.The affected sides were selected as case group,and the healthy sides as control group.The hardness and maximum Young's modulus values on both affected sides and healthy sides of patients before treatment as well as on the affected sides after 3 weeks of treatment were measured and recorded by gray-scale ultrasound and SWE technology,and the results were statistically analyzed.Results Before treatment,the maximum Young's modulus values of the affected sides of 30 patients were higher than those of the healthy sides,and the maximum Young's modulus values of the affected sides after 3 weeks of treatment were lower than those before treatment,difference was statistically significant(all P<0.001).There was no statistically significant difference in the hardness of AT between the healthy sides before treatment and the affected sides after 3 weeks of treatment(all P>0.05).Pearson correlation analysis showed that there was no significant correlation between the maximum Young's modulus values of the AT and the hardness of AT on affected sides before treatment and 3 weeks after treatment among the 30 patients(r=0.240,r=0.167,all P>0.05).Conclusion SWE technology can quantitatively assess the changes in the elasticity of the Achilles tendon in stroke patients,provide clinical quantitative indicators for the Achilles tendon,and guide rehabilitation.

关 键 词:脑卒中 跟腱 剪切波弹性成像技术 杨氏模量值 硬度 

分 类 号:R493[医药卫生—康复医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象