摘 要:介绍了STA449F3同步热分析仪的工作原理和操作条件。结合实际工作对仪器在使用过程会出现的故障进行了分析和探讨,指出了针对故障的具体解决方案。合理有效的管理维护,可得到准确的测试结果,延长仪器使用寿命,降低实验室消耗。The principles and operation conditions of STA449F3 simultaneous thermal analyzer were introduced.Combined with practical working experience,the common malfunctions during instrument manipulation were analyzed and discussed.Moreover,the effective solutions were proposed.It is known that reasonable management and maintenance can obtain accurate results,prolong service life and reduce laboratory consumption.