检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈明 唐原君 王倩茹 唐晶晶 石晨阳 CHEN Ming;TANG Yuan-jun;WANG Qian-ru;TANG Jing-jing;SHI Chen-yang(Department of Clinical Pharmacy,Shanghai General Hospital,Shanghai Jiao Tong University,Shanghai 200080,China;Chongqing Medical University,Chongqing 500010,China;Department of Clinical Pharmacy,Jiangqiao Hospital,Shanghai 201800,China)
机构地区:[1]上海交通大学附属第一人民医院临床药学科,上海200080 [2]重庆医科大学,重庆500010 [3]上海市嘉定区江桥医院,上海201800
出 处:《实用药物与临床》2021年第10期933-937,共5页Practical Pharmacy and Clinical Remedies
摘 要:目的应用质控图联合Westgard多规则法评估替考拉宁血药浓度监测的室内质量控制,提高治疗药物监测质量。方法回顾性统计2019年1-6月62组替考拉宁高、中、低浓度的随行质控品的实测浓度,分别绘制Levey-Jennings质控图和Z-分数质控图,采用Westgard多规则理论进行室内质量控制的评估。结果替考拉宁低、中、高室内质控的日内和日间RSD分别为1.92%~3.81%和2.84%~3.83%,回收率分别为105.42%~106.97%和102.98%~105.33%,符合生物样品检测的要求。绘制的Levery-Jennings质控图和Z-分数质控图通过Westgard多规则法评估显示,低、中、高浓度质控血浆样品均未出现失控,替考拉宁治疗药物监测结果准确可靠。结论建立的替考拉宁血药浓度监测室内质量控制体系,具有较好的精密度和准确性,对提高临床用药的安全合理性具有重要意义。Objective To improve the quality of therapeutic drug monitoring by evaluating the indoor quality control of teicoplanin blood concentration monitoring with Westgard multi-rule theory based on the quality control chart.Methods The actual concentrations of 62 groups of accompanying quality control samples with high,medium and low concentrations of teicoplanin from January to June in 2019 were retrospectively counted.The indoor quality control was evaluated by Westgard multi-rule theory based on analyzing Levey-Jennings quality control charts and Z-score quality control chart.Results The intra-day RSD of teicoplanin was 1.92%~3.81%,the inter-day RSD was 2.84~3.83%,and the recovery rates were respectively 105.42%~106.97%and 102.98%~105.33%,which met the requirements for biological sample determination.Levey-Jennings control charts and Z-score control chart were evaluated by Westgard multi-rule theory,which showed that there was no loss of control in low,medium,or high-concentration quality control plasma samples,and the results of teicoplanin were accurate and reliable.Conclusion The indoor quality control system of monitoring of teicoplanin blood concentration is of good precision and accuracy,which is of great significance to improve the safety and rationality of clinical medication.
关 键 词:替考拉宁 质控图 Westgard多规则理论 治疗药物监测 室内质控
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3