综合污水处理厂混凝剂用量实验研究  

Experimental Study on Coagulant Dosage at Comprehensive Sewage Treatment Plant

在线阅读下载全文

作  者:刘忠成 王军强[2] 于丰浩 陈冬梅 韩彬 LIU Zhong-cheng;WANG Jun-qiang;YU Feng-hao;CHEN Dong-mei;HAN Bin(Safety and Environment Department ofAngang Group Co.,Ltd.;Angang Group Engineering&Technology Co.,Ltd.;Beijing Zhongke Shengtai Environmental Technology Co.,Ltd.,Anshan 114000)

机构地区:[1]鞍山钢铁集团有限公司安环部 [2]鞍钢集团工程技术有限公司 [3]北京中科圣泰环境科技有限公司,鞍山114000

出  处:《冶金设备管理与维修》2021年第5期55-57,共3页Metallurgical Equipment Management and Maintenance

摘  要:某钢厂综合污水处理厂来水类型复杂、多样,为使混凝预处理后水质达到后序超滤膜单元进水要求,延长超滤膜系统使用寿命,针对两种不同来水水样进行了PAC和PAM混凝实验,确定了最佳药剂投放比例,黑红色水样最佳投药比例为25mg/L PAC和2mg/L PAM,黑灰色水样最佳投药量为25PAC和1.5mg/L PAM。The types of water samples are complex and diverse at a comprehensive sewage treatment plant of steelmaking plant.The PAC and PAM coagulation experiments were carried out for two different water samples,in order to make the water quality to meet the inflow requirements o£the post-sequency ultrafiltration membrane unit after coagulation pretreatment and prolong the service lifetime of ultrafiltration membrane system.The optimal dosage ratio is confimied.The best dosage ratio of black-red water sample is 25mg/L PAC and 2mg/L PAM,and the best dosage ratio of black-grey water sample is 25PAC and 1.5mg/L PAM.

关 键 词:PAC PAM 混凝 污水处理 

分 类 号:X70[环境科学与工程—环境工程]

 