检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王泽港 王康谊[1] WANG Zegang;WANG Kangyi(School of Information and Communication Engineering,North China University,Taiyuan 030051,China)
机构地区:[1]中北大学信息与通信工程学院,太原030051
出 处:《实验室研究与探索》2021年第9期101-104,共4页Research and Exploration In Laboratory
摘 要:为了解决弹载记录仪供电设备的国产化及试验过程中出现的供电不足与突然掉电问题,确保试验结果的准确性,根据设备的性能和功能要求,对系统电路进行总体设计;比较分析国内多款芯片,选用了5.5 V充电的国产超级电容芯片和5V输出的国产升压芯片。通过试验比较,弹载记录仪供电设备能够进行电压检测,记录仪掉电及时预警;采取相关延时供电方案,保证后续数据采集的完整性。The power supply equipment of missile borne recorder is an important part of missile test.The localization and stability of the power supply equipment directly affect the test results.This paper completes the localization of power supply equipment of missile borne recorder and the situation of insufficient power supply and sudden power failure during the test to ensure the accuracy of test results.Firstly,according to the performance requirements and functional requirements of the equipment,the overall design of the system circuit is carried out,and then a number of domestic chips are compared and analyzed.The domestic super capacitor chip with 5.5 V charging and domestic boost chip with 5 V output are selected.Through the test and comparison,the power supply equipment of missile borne recorder can detect the voltage and timely warn the recorder when it is powered down;and adopt relevant delay power supply scheme to ensure the integrity of subsequent data acquisition.
关 键 词:弹载记录仪 直流不间断电源 过压保护 掉电检测 延时供电
分 类 号:TM910.2[电气工程—电力电子与电力传动] TM919
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:52.15.179.198