弹套莫菲氏滴壶式微型智能输液报警器在静脉输液中的应用观察  被引量:3

Application of micro intelligent infusion alarm with elastic sleeve Murphy dropping pot in intravenous infusion

在线阅读下载全文

作  者:欧阳威[1] 钟冬秀[2] 罗峰[3] 谢宗越 刘小丽 OUYANG Wei;ZHONG Dong-xiu;LUO Feng;XIE Zong-yue;LIU Xiao-li(Experimental Teaching Center of Information Engineering College,Gannan Medical University;Department of Medical Affairs,the First Affiliated Hospital of Gannan Medical University;Department of Obstetrics and Gynecology,the First Affiliated Hospital of Gannan Medical University;Nursing Teaching and Research Office of Gannan Health Vocational College,Ganzhou,Jiangxi 341000)

机构地区:[1]赣南医学院信息工程学院实验教学中心 [2]赣南医学院第一附属医院医务科 [3]赣南医学院第一附属医院妇产科 [4]赣南卫生健康职业学院护理系儿内科护理教研室,江西赣州341000

出  处:《赣南医学院学报》2021年第10期1040-1042,共3页JOURNAL OF GANNAN MEDICAL UNIVERSITY

基  金:江西省科技厅应用研究培育计划项目(20181BBG78031);国家实用新型专利(201621071249.2,202120269373.4);国家外观专利(201630478966.6)。

摘  要:目的:观察弹套莫菲氏滴壶式微型智能输液报警器在静脉输液中的应用效果。方法:选取220例静脉输液患者,随机分成观察组与对照组,各110例。对照组采用常规方法进行输液护理,观察组在常规输液护理的基础上,在输液管莫菲氏滴壶处套上微型智能输液报警器进行电子监控,观察两组输液过程中出现的问题指标情况,调查观察组患者及护士使用报警器满意度。结果:观察组输液监控问题指标如滴速误差、针头阻塞、液体滴空、针头回血及输液部位肿胀均优于对照组,差异有统计学意义(P<0.05)。观察组患者及护士使用报警器满意度分别为92%、91%。结论:弹套莫菲氏滴壶式微型智能输液监护器临床应用效果显著,可提高输液安全性。Objective:To observe the application effect of Mulfield's drip pot miniature intelligent infusion alarm in intra⁃venous infusion.Methods:A total of 220 cases with intravenous fluids were included in the study.They were randomly divided into observation group(n=110)and control group(n=110).The control group used conventional methods to transfusion nursing,observation group was based on the basis of conventional infusion nursing,also with in iv murphy's cover on the micro intelligent infusion alarm device for electronic monitoring,observing the problems of the two groups arising from the infusion process index,the satisfaction of patients and nurses in the observation group.Results:The in⁃dicators of infusion monitoring in the observation group were better than those in the control group,such as drip rate er⁃ror,needle obstruction,fluid emptiness,needle blood return and infusion site swelling(P<0.05),the difference was statistically significant.The satisfaction rates of patients and nurses in the observation group were 92%and 91%,respec⁃tively.Conclusion:the application of the miniature intelligent infusion monitor of Murphy's drip pot with a bomb case is very effective.It can improve the safety of infusion,and is worthy of popularization.

关 键 词:微型智能输液监护器 静脉输液 